13. Parameter Description
P
Depends on pole number
B10
; f
max
= 400 Hz. With a 4-pole motor:, this is 12000 rpm at 400 Hz.
•
The power pack must be turned off before these parameters can be changed.
Italics
These parameters are sometimes not shown depending on which parameters are set.
1)
See result table in chap. 15.
2) Only available if
D90
≠
1
Parameters which are included in the
normal
menu scope (
A10
=0). For other parameters, select
A10
=1:
extended
or
A10
=2:
service
.
Parameters marked with a "
√
" can be parameterized separately from each other in parameter record 1 and 2.
52
J.. Posi. Command (Process Blocks)
Para. No. Description
J18
Delay:
Parameter only available if
J15
≠
0 or
J16
≠
0 and
J17
=1. Otherwise not shown.
Delay before the repetition of relative movements (
J15
≠
0) or before automatic change to the next record
(
J17
=
1:with delay
). After expiration of the delay time, movement is automatically resumed. A delay can be
terminated (i.e., shortened) with the
posi.step
signal (rising edge).
Value range in sec:
0 to 65.535
Ö
The process block no. 2 - no. 8 are identical. Process block no. 2 is at
J20
-
J28
, process block no. 3 at
J30
-
J38
etc.
L.. Posi. Command 2 (Expanded Process Block Parameters)
Para. No. Description
L10
Brake:
Definition for process block no. 1. Only if
F00
=1. Process block-related brake control (e.g., for lifting
systems). After reaching destination position
J10
, you can apply the brake controlled via relay 2.
0: inactive;
Destination position is held by the motor (i.e., position control). Brake is only applied when enable,
halt, quick stop or fault is missing.
1: active;
After the destination position is reached, the brake is automatically applied. The next start command is
delayed by the time
F06
(brake release). With
B25
=0 and applied brake, power can be disconnected from the
motor so that it can cool off while waiting, for example.
L11
Switch A:
Selection of the first switching point for process block no. 1. Up to two switching points ("switch A"
and "switch B") can be used in each process block. Each of the four switching points defined in group
N
.. can be
used in various process blocks. Cf. chap. 10.12.
0: inactive;
1: switch S1;
2: switch S2;
3: switch S3;
4: switch S4;
L12
Switch B:
Selection of the second switching point for process block no. 1. Cf.
L11
.
Value range:
0 to 4
Ö
Extended process block parameter are identical for all process blocks. Process block no. 1 is located at
L10
...
L12
, process
block no. 2 at
L20
...
L22
, and so on.
M.. Menu Skip (Menu jump destinations)
Para. No. Description
M50
F1-jump to:
Parameter provided by the F1 function key for editing. Depending on the device function, some
parameters may not be shown and cannot be selected.
Value range:
A00
to
E50
to
N44
M51
F1-lower limit:
Value range:
depends on the parameter selected in
M50
M52
F1-upper limit:
Value range:
depends on the parameter selected in
M50
Ö
The jump destinations F2 to F4 are designed identically. Jump destination F2 is in
M60
to
M62
, and so on.
If several jump destinations (
M50
;
M60
;
M70
or
M80
) are parameterized to the same coordinates (e.g.,
J10
), the lower, upper
limit of the lowest jump destination takes effect.