Connection
Projecting manual POSIDRIVE® FDS 5000
ID 442269.07
WE KEEP THINGS MOVING
93
5
5.13.4
X200, X201: PROFINET
Requirement for the die PROFINET connection:
•
PN 5000
X200 and X201 terminal description
The terminal configuration is determined by T 568-B.
Observe the PROFINET installation guideline for the cable specification (PROFINET Order No. 8.071,
identification: TC2-08-0001); you can obtain the document at www. profibus.com.
Information
Observe the PROFINET operating manual (see section 1.2 Further documentation)!
Pin
Designation
Function
1
PROFINET communication
2
TxData -
3
Re
4
—
Connect via RC-link with housing
5
—
6
RecvData -
PROFINET communication
7
—
Connect via RC-link with housing
8
—