background image

Page 3

Due to continuous product research and development,

the information contained herein is subject to change without notice.

www.stoddart.com.au

www.stoddart.co.nz

Thank you for choosing this quality Culinaire product�
All Culinaire products are designed and manufactured to meet the needs of food service professionals�  By caring for and maintaining your 
new Culinaire product in accordance with these instructions, will provide many years of reliable service�

Stoddart is a wholly Australian owned company, which manufactures and/or distributes a comprehensive range of food service equipment for
kitchens, food preparation and presentation�  Stoddart products are manufactured and/or engineered in Australia to provide excellent results 
whilst offering value-for-money, ease-of-use and reliability�

Carefully read this instruction booklet, as it contains important advice for safe installation, operation and maintenance� 

Keep this booklet on hand in a safe place for future reference by other operators or users�

Stoddart design, manufacture & distribute Food Service Equipment (appliances) exclusively for the commercial market.

This appliance is not designed nor intended for household or domestic use and must not be used for this purpose.

This product is intended for commercial use, and in line with Australian electrical safety standards the following warnings are provided:

•  This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person 
responsible for their safety� Children should be supervised to ensure that they do not play with the product

•  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid 

a hazard

The manufacturer and distributor cannot be held responsible or liable for any injuries or damages of any kind that occur 

to persons, units or others, due to abuse and misuse of this unit in regards to installation, removal, operation, servicing or 

maintenance, or lack of conformity with the instructions indicated in this documentation�

Disclaimer

All units made by the manufacturer are delivered assembled, where possible, and ready to install� Any installation, removal, 
servicing, maintenance and access or removal of any parts, panels or safety barriers that is not permitted, does not comply 

in accordance to this documentation, or not performed by a 

TRAINED AND AUTHORISED SPECIALIST

 will result in the

IMMEDIATE LOSS OF THE WARRANTY.

The manufacturer cannot be held responsible or liable for any unauthorised modifi cations or repairs� All modifi cations or 

repairs must be approved by the manufacturer in writing before initiating� All modifi cations or repairs performed to this unit 

must be performed at all times by a 

TRAINED AND AUTHORISED SPECIALIST.

Your New Culinaire Product

To register your new product, Follow the below Link/QR code�

www�stoddart�com�au/warranty-information

All Stoddart manufactured and distributed products are covered by Stoddart’s standard Australia and New Zealand Product Warranty (minimum 
12 month on-site parts and labour, terms and conditions apply)� Further to this standard warranty, certain products have access to an extended 
warranty� Full terms, conditions and exclusions can be found using the below Link/QR code�

Warranty & Registration

Introduction

Summary of Contents for CR.GC1.L.RC.L

Page 1: ...R GC1 L RC R CR GC1 L RCL R CR GC1 L RCL R CR GC1 S RC L CR GC1 S RC R CR GC1 S RCL R CR GC1 S RCL R CR GC2 L RC CR GC2 L RCL CR GC2 S RC CR GC2 S RCL GLASS CHILLER REMOTE SINGLE DOUBLE DOOR SPECIFICA...

Page 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Page 3: ...Liquid Line Isolation Valves Refrigeration Lines Condenser Unit Remote Unit Leak Testing Diagram Climate Classes Electrical Connection 10 Plumbing Connections 10 Specification Technical Specification...

Page 4: ...s not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction con...

Page 5: ...g The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unreasonable use of the machine Only specifically trained qualified Technicians Stoddart...

Page 6: ...d GC Glass Chiller 1 2 1 door 2 door L S Lift of lid Sliding Lid RC Right Hand Remote Service Compartment RCL Left Hand Remote Service Compartment L R Left Right hand hinged door Control Panel Install...

Page 7: ...nit using a clean cloth dampened with warm soapy water When moving the unit ensure the cabinet is upright at all times When positioning the unit avoid direct sunlight warm drafts and heated areas for...

Page 8: ...d valve Isolation valves suction line and liquid line are not sold or supplied with this product or by Stoddart For purchasing and installation of the solenoid contact a local refrigeration company En...

Page 9: ...d fill with dry nitrogen to 1725kPa 250psi Close the pressure gauge and note the pressure reading Using a soapy solution check all the joints for leaks If leaks exist START If leaks exist If NO leaks...

Page 10: ...3M1 Refrigerated Units in Commercial Kitchens would normally be climate class 4 CLIMATE CLASSES Test Room Climate Class Dry bulb temperature C Relative humidity Dew point C Water weightin dry air g k...

Page 11: ...this manual require the power to the equipment to be turned o and isolated Turn the power OFF at the power point and unplug the power supply lead by the plug body If the power point is not readily acc...

Page 12: ...TIONS Model CR GC1 L RC L CR GC1 L RC R CR GC1 L RCL L CR GC1 L RCL R CR GC1 S RC L CR GC1 S RC R CR GC1 S RCL L CR GC1 S RCL R Width 760mm Depth 668mm Height 880mm Voltage Frequency 240V 50Hz Power k...

Page 13: ...ww stoddart com au www stoddart co nz Specification SPECIFICATIONS Model CR GC2 L RC CR GC2 L RCL CR GC2 S RC CR GC2 S RCL Width 1200mm Depth 668mm Height 880mm Voltage Frequency 240V 50Hz Power kW 0...

Page 14: ...g the cabinet should not occur through the lid s Ensure the doors are CLOSED when not loading to maintain the temperature The cabinet should only be loaded with 14 x 14 and 14 x 17 glass baskets The r...

Page 15: ...sed on The unit will maintain a default temperature after service for instant use the next day Switch OFF lights and door heaters to minimise power Ensure all doors are closed Defrost Cycle The system...

Page 16: ...room temperature display KEY COMBINATIONS 1 Push and immediately release the SET key the display will show the set point value 2 Push and immediately release the SET key or wait 5 seconds to display...

Page 17: ...is unit is NOT waterproof DO NOT hose DO NOT pour water directly onto the unit DO NOT immerse in water Stainless steel exhibits good resistance to corrosion however if not properly maintained stainles...

Page 18: ...Do NOT let water pool check crevices and folds Doors Night Lids 1 Use a vacuum to remove dust and debris from all the ventilation panels 2 Do NOT use water or a hose to remove dust or debris Ventilati...

Page 19: ...uit board Refrigeration circuit board s is hot T Replace Fix circuit board s Unit is too warm Ambient air entering the units O Door not closing sealing O Move unit exhaust fan O Open baffle Warm items...

Page 20: ...tor retailer can contact their local metal recycling centre to collect the remaining cabinet shelves etc There may be special requirements or conditions Information on the disposal of refrigeration ap...

Page 21: ...Page Intentionally Left Blank Page 20 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Page 22: ...Page 21 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Page 23: ...Page 22 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Page 24: ...7694 New Zealand Sales Spare Parts Tel 0800 79 1954 Email sales stoddart co nz Email spares stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz...

Reviews: