D. The floor model freezers are equipped with air-cooled
condensers and require correct ventilation. The front of
the freezer is the air intake and must be unobstructed.
Air discharges out of the rear of the unit. Do not obstruct
the discharge. Allow a 6" (15.2 cm) clearance behind
the unit (Fig. 8).
CAUTION
Risk of product damage
Air cooled condenser requires proper ventilation. Fail-
ure to provide adequate ventilation will void factory
warranties.
E. Place the ON-OFF-STIR ONLY toggle switch in the
OFF position. This switch is located on the lower left of
the freezer, under the drip tray and cover.
F. Connect the power cord. The plug is designed for 115
volt/15 amp duty. The unit must be connected to a
properly grounded receptacle. The electrical cord
furnished as part of the freezer has a three prong
grounding type plug (Fig.9). The use of an extension
cord is not recommended. If one must be used, use one
with a wire, size 12 gauge or heavier, with a ground. Do
not use an adaptor to avoid grounding equipment.
Figure 8
Space and Ventilation Requirements
Figure 10
Installing Sani-tray and Cover
Figure 9
Electrical Plug
WARNING
Do not alter or deform electrical plug in any way.
Altering the plug to fit into an outlet of different configu-
ration may cause fire, risk of electrical shock, product
damage and will void the warranty.
G. Install the sani-tray, cover and miscellaneous
parts on the freezeer (Fig. 10).