C. MONTHLY
CAUTION
The freezer has an air cooled condenserand must
have proper air circulation. Maintain a minimum
of 3" clearance at all louvered panels. Failure to
clean the condenser filter on a regular basis and
provide proper clearance may result in serious
freezer damage and may void any factory war-
ranties.
1.
Remove the condenser filter by lifting up and pulling
bottom out and down. Then clean with warm soapy
water. Rinse in clean water and shake dry, taking
care not to damage the filter in any way.
2.
Replace the condenser filter.
D. SEMIANNUALLY
WARNING
High voltage will shock, burn or cause death.
Turn off and lock out main power disconnect
before servicing. Do not operate machine with
cabinet panels removed.
WARNING
Moving machine parts can grab, mangle, dis-
member and cause severe crushing injury. Turn
off and lock out main power disconnect before
cleaning or servicing. Do not operate machine
with cabinet panels removed.
1.
Check drive belt for proper tension. Push belt in with
one finger, belt should deflect about 3/8".
CAUTION
Do not over-lubricate condenser fan motor. Ex-
cess oil may damage motor and void any factory
warranties.
2.
Lubricate condenser fan motor with S.A.E. 20 weight
oil. Three to six drops is required.
3.14 EXTENDED STORAGE
Refer to the following steps for storage of the freezer over
any long period of shutdown time:
A. Turn the OFF-ON switch to the OFF position.
B. Disconnect (unplug) from the electrical supply source.
C. Clean thoroughly with a warm detergent all parts that
come in contact with the mix. Rinse in clean water and
dry parts. Do not sanitize.
NOTICE
Do not
let the cleaning solution stand in the hopper or in
the freezer barrel during the shutdown period.
D. Remove, disassemble and clean the front door, mix
inlet regulator and auger parts. Place the auger flights
and the front auger support bushing in a plastic bag
with a moist paper towel to prevent them from becom-
ing brittle.