22
ERROR CONDITION CODE 07
If the control panel displays a Drive Motor Current error
(Error Code 07), place the Freezing Cylinder Off-On
Switch in the Off position, wait 10 seconds, and return the
switch to the On position. If the Control Panel still displays
the error condition code, call your Authorized Stoelting
Distributor for further assistance.
ERROR CONDITION CODE 09 (water cooled models only)
Error 09 conditions are usually caused by insufficient
cooling at the freezer's condenser. If the control panel
displays a High Pressure Cutout error (Error Code 09),
turn the freezer power off. Press the High Pressure Cutout
Reset Switch located on the upper, left hand corner of the
left side panel. There is a round, black boot covering the
reset switch. Pressing in the center of the boot will reset
the switch.
Check for proper waterflow through the condenser coil.
After the cause of the error is determined and corrected,
place the Freezing Cylinder switch to the On position. If the
Control Panel still displays the error condition code, call
your Authorized Stoelting Distributor for further assis-
tance.
ERROR CONDITION CODE 12
If the control panel displays a left hopper sensor error
(Error Code 12), place the Freezing Cylinder Off-On
Switch in the Off position, wait 10 seconds, and return the
switch to the On position. If the Control Panel still displays
the error condition code, call your Authorized Stoelting
Distributor for further assistance.
ERROR CONDITION CODE 13
If the control panel displays a right hopper sensor error
(Error Code 13), place the Freezing Cylinder Off-On
Switch in the Off position, wait 10 seconds, and return the
switch to the On position. If the Control Panel still displays
the error condition code, call your Authorized Stoelting
Distributor for further assistance.
ALTERNATING FLASHING CONTROL PANEL LIGHTS
When the right Freezing Cylinder OFF/ON switch is
placed in the ON position and the left Freezing Cylinder
OFF/ON switch is left in the OFF position, the green and
amber control panel lights will flash in alternating se-
quence and the message "Frz Cyl Hprs Of" will display
on the LCD panel. This indicates that the right freezing
cylinder is receiving power, but the hoppers are not be-
ing refrigerated. Placing the left Freezing Cylinder OFF/
ON switch in the ON position will return the left freezing
cylinder to the SLEEP mode, and keep the hoppers re-
frigerated.