17
4.1 MACHINE
ADJUSTMENT
This section is intended to provide maintenance personnel
with a general understanding of the machine adjustments.
It is recommended that any adjustments in this section
be made by a qualifi ed person.
4.2 PRODUCT
CONSISTENCY
ADJUSTMENT
The operator can adjust product consistency by modify-
ing the Fine Adjustment setting on the membrane switch.
This is the only adjustment that can be made by the op-
erator without using a pass code key sequence. Product
consistency fi ne adjustment allows a 0.4 amp maximum
adjustment to the drive motor amp draw cutout. Increasing
this setting will increase the drive motor amperage cutout
and increase product consistency. Follow the instructions
below to make fi ne adjustments to product consistency.
A.
Place the Main Freezer Power switch in the ON
position.
B.
Press the SET button on the Control Panel once.
Fine Adj will appear on the LCD screen.
C.
Press the up arrow button
until the desired
consistency setting is displayed. The higher the
number, the fi rmer the product consistency. The
control may be set from 1 to 9. The value increases
by 1 each time the up arrow button is pressed.
After the value reaches 9, numbering restarts at
0. The 0 setting cannot be set.
D.
Press the SET button once to save the setting
and return to the current mode display.
SECTION 4
MAINTENANCE AND ADJUSTMENTS
4.3
LOCKING THE CONTROL PANEL
The IntelliTec control has a tamper proof mode to prevent
unauthorized use. When set, all buttons on the control
panel are disabled. Follow the instructions below to lock
the control panel
A.
Press and hold the PUSH TO FREEZE button
for at least 5 seconds.
B.
While still holding the PUSH TO FREEZE button,
press the CLEAN button once.
C.
Release both buttons. An asterisk (*) will appear
on the bottom line of the display, indicating that
the control is in the lock out mode.
NOTE:
Repeat steps A, B, and C to unlock the control
panel.
4.4 OBTAINING
READINGS
AND
MODIFYING SETTINGS (SERVICE PERSONNEL
ONLY)
Readings and settings on the IntelliTec control are ac-
cessed through the IntelliTec control menu settings.
Locating machine readings and system function settings
are done using the up arrow (
) and left arrow (
) but-
tons on the membrane switch. A printed IntelliTec Menu
Settings sheet is located in the information pouch behind
the header panel.
IntelliTec Control Readings
To obtain machine readings, locate the value on the ma-
chine’s menu settings sheet and follow the steps below.
A.
Press and hold the SEL button for 8 seconds. While
still holding the SEL button, press the up arrow
button (
). The LCD screen will read DISPLAY.
B.
Release both buttons.
C.
Press the up arrow button (
) to navigate to the
correct reading under DISPLAY or press the left
arrow (
) button to navigate to the ERRCODES
menu.
D.
Press the up arrow (
) and left arrow (
) buttons
to navigate through the rest of the readings as
needed.
E.
When all readings have been obtained, press
the up arrow button (
) from ExitMenu to return
to the current mode display.
Modifying Control Settings
To change the value of a system function, locate the
function on the IntelliTec Settings Menu and follow the
steps below.
Figure 4-1 Touchpad