6
2.
Slide the hose clip over free end of 3/8” (9,5mm)
ID plastic food grade tubing. Attach the free end
of the tubing to a manifold adapter. Secure with
a large hose clamp or equivalent.
3.
Push the manifold adapter with spring and valve
into the left port (nearest the manifold outlet) of
the mix inlet manifold and secure with a retaining
clip.
4.
Repeat steps 1 to 3 for the middle port and for
the right port of the mix inlet manifold.
5.
Place three mix bags into the mix container.
6.
Connect the bag adapter attached to the left side
of the manifold (closest to the mix outlet) to the
mix bag in the back of the mix container.
7.
Connect the bag adapter attached to the middle
of the manifold to the mix bag in the middle of
the mix container.
8.
Connect the bag adapter attached to the right
side of the manifold (farthest from the mix outlet)
to the mix bag in the front of the mix container.
When Using Bag Connection
System (BCS) with One or Two
Bags (optional kit):
When connecting one or two
bags, the manifold adapters
must be installed closest to the
manifold outlet and the manifold
plug(s) must be placed farthest
from the manifold outlet.
1.
Connect 3/8” (9,5mm) ID
plastic food grade tubing
to a bag adapter. Secure
with hose clamps.
2.
Slide the hose clip
over the free end of
the tubing. Attach the
free end of the tubing
to a manifold adapter.
Secure with a large hose
clamp.
3.
P u s h t h e m a n i f o l d
adapter with spring and
valve into the left port
(nearest the manifold
outlet) of the mix inlet
manifold and secure
with retaining clip. (See
Figure 2-4).
4.
If using two mix bags,
repeat steps 1 to 3 for
the middle port.
5.
Install a manifold plug
into each empty inlet and
secure with a retaining
clip.
Figure 2-4 Bag Connection System (Optional)
Bag Adapter
Manifold
Adapter
Retaining
Clip
Mix Inlet
Manifold
Manifold
Plug
6.
Place the mix bag(s) into the mix container.
7.
Connect the bag adapter attached to the left side
of the manifold (closest to the mix outlet) to the
mix bag in the back of the mix container.
C. MIX LOW LEVEL INDICATOR ADJUSTMENT
The sensitivity of the “Mix Low” indication can be adjusted
to operator preference. If more advanced notice of low mix
is required, loosen the black adjustment knobs located on
the sensor brackets at the back of the machine cabinet
and slide the bracket upwards. If the “Mix Low” message
(right side) or fl ashing light (left side) appears while there
is still suffi cient mix in the container, slide the bracket
downward. Be sure to tighten the adjustment knobs after
properly positioning the sensor.