12
3.
Remove the air bleed valve by unscrewing the
knob while holding the valve stem from behind.
Remove the compression spring and push the
air bleed valve through the rear of the front door.
4.
Remove the spigot through the bottom of the front
door. Remove all o-rings from the spigot and the
air bleed valve.
5.
Remove the plastic bearing. The plastic bearing
may be on the front door.
6.
Remove the auger by pulling slowly. Be careful
not to scratch the inside of the freezing cylinder
when removing the auger.
7.
Keep the rear of the auger tipped up once it is
clear of the freezing cylinder to prevent the rear
seal assembly from dropping.
8.
Wipe the hex drive anti-seize off the hex end of
the auger with a paper towel. Remove the rear
seal assembly.
NOTE
Keep the rear seal assembly separate from the
right side assembly to prevent problems when as-
sembling.
3.6 CLEANING DISASSEMBLED PARTS
Disassembled parts require complete cleaning, sanitiz-
ing and air drying before assembling. Local and state
health codes will dictate the procedure required. Some
state health codes require a four sink process (pre-wash,
wash, rinse, sanitize, air dry), while others require a three
sink process (without the pre-wash step). The following
procedures are a general guideline only. Consult your
local and state health codes for the procedures required
in your location.
A.
Disassemble all parts.
B.
Place all front door and auger parts in clean 90° to
110°F (32°C to 43°C) water and wash thoroughly
(four sink procedure only).
CAUTION
The blender motor cannot be immersed in water
or sanitizer. Wash the motor and mounting bracket
with a mild detergent solution taking care not to al-
low water into the motor bearings or seals.
C.
Place all parts in 90° to 110°F (32°C to 43°C) mild
detergent water and wash thoroughly.
D.
Rinse all parts with clean 90° to 110°F (32°C to
43°C) water.
E.
Sanitize all machine parts following procedures
outlined below.
3.7 SANITIZING PARTS
A.
Use a sanitizer, mixed according to manufacturer’s
instructions, to provide a 100 parts per million
strength solution. Mix sanitizer in quantities of
no less than 2 gallons of 90° to 110°F (32°C to
43°C) water. Any sanitizer must be used only in
accordance with the manufacturer’s instructions.
B.
Place all parts in the sanitizing solution for 5
minutes, then remove and let air dry completely
before assembling in machine.
3.8 CLEANING THE MACHINE
The exterior should be kept clean at all times to preserve
the luster of the stainless steel. A high grade of stainless
steel has been used on the machine to ease cleanup. To
remove spilled or dried mix, wash the exterior with 90° to
110°F (32°C to 43°C) soapy water and wipe dry.
Do not use highly abrasive materials, as they will mar the
fi nish. A mild alkaline cleaner is recommended. Use a soft
cloth or sponge to apply the cleaner. For best results, wipe
with the grain of the steel.
A.
Clean the rear seal surfaces on the inside of the
freezing cylinders.
B.
Using sanitizing solution and the large barrel
brush provided, sanitize the freezing cylinders by
dipping the brush in the sanitizing solution and
brushing the inside of the freezing cylinders.
C.
Remove the drip trays from the front panel. Clean
and replace the drip trays.
3.9 ASSEMBLING THE LEFT SIDE
Refer to the following steps for assembling the left freez-
ing cylinder:
NOTICE
Petrol-Gel sanitary lubricant or equivalent must be
used when lubrication of machine parts is specifi ed.
NOTICE
The United States Department of Agriculture and
the Food and Drug Administration require that lubri-
cants used on food processing equipment be certi-
fi ed for this use. Use lubricants only in accordance
with the manufacturer’s instructions.
A.
Assemble all o-rings onto parts dry, without
lubrication. Then apply a thin fi lm of sanitary
lubricant to exposed surfaces of the o-rings.
B.
Install the rear seal o-ring. Lubricate the outside
of the rear seal o-ring with sanitary lubricant.