English
Operating instructions
11
-
Open the lid, unscrew the fixing knob [7], pull out the beater [6] from the cylinder, then close the lid.
Note:
The device will not operate when the lid is open.
-
Press the BEATING Pushbutton [K2] and check that beater’s shaft turns CLOCKWISE (as shown in the picture). In
this case, the device is correctly connected and ready to be used;
Note:
do not unnecessarily start the refrigerating system.
-
If the rotation is COUNTERCLOCKWISE, the connection to the three-phase electrical supply is wrong, and
must be changed proceeding as follows:
-
Turn off the device by pressing the ON/OFF Pushbutton [K1];
TURN THE SOCKET'S BREAKER ON “0” POSITION, THEN UNPLUG
THE MACHINE;
-
Open the plug’s shell and invert TWO of the THREE conductors connected at the
phases (R- S, R- T or S- T);
-
Close the plug’s shell, plug in the device and repeat the checking.
6
M
ACHINE
’
S OPERATION
6.1
Warnings
WHEN USING THE DEVICE, AS WITH ALL ELECTRICAL APPARATUS, ESSENTIAL RULES MUST BE
COMPLIED WITH, PARTICULARLY:
-
never touch it if your feet or hands are wet;
-
never operate it while barefoot;
-
never pull the supply cable to disconnect it from the main network;
-
avoid liquids to penetrate in the device, for example during its cleaning;
-
forbid children and unable people to operate it.
In case of failure and/or malfunctioning of the device - and every time you notice damages, mainly at the supply cable or at
the safety devices - turn off the power supply. Contact qualified and certified personnel for assistance.
NEVER operate the machine in DRY conditions or with an amount of mixture other than the one recom-
mended.
NOT RESPECTING THESE RULES, IN ADDITION TO VOIDING ANY FORM OF WARRANTY, CAN SERI-
OUSLY COMPROMISE THE SAFETY, PERFORMANCES AND FUNCTIONING OF THE SAME DEVICE.