4.5 Serial Interface
The C11/G2 provides a serial interface which is used to connect a
communication device for transmitting data or a PC for controlling the
C11/G2. The serial interface corresponds to the V.24/RS-232 standard
and supports the following features:
•
Transmission speed: 300 – 921.600 bps (asynchronous)
•
Character representation: 7/8 bit, no/even/odd/mark/space parity, 1 or 2 stop bits
•
Hardware flow control with RTS/CTS
The C11/G2 can be used in DTE or DCE mode. This requires a special
setting in the firmware. The selection of the appropriate D-SUB socket is made by
jumper J2.20.
Jumper
Position
Function
1-2
DCE socket selected
J3.7
2-3
DTE socket selected
4.6 Connectors/Jumpers
4.6.1 Jumper J1
Jumper J1 is used for signal routing.
Jumper Number Position Description
J1.1
Open
Not used
J1.2
2-3
connect PIO9 to LED2
J1.3
Open
Not used
J1.4
2-3
connect PIO7 to LED1
J1.5
2-3
PIO 6 - RI for DTE and DCE connected to V.28
J1.6
2-3
PIO 14 - DTR (DTE) and DSR (DCE) output
connected to DTE/DCE socket
J1.7
2-3
PIO 13 - DSR (DTE) and DTR (DCE) input
connected to DTE/DCE socket
J1.8
2-3
GPIO 15 - DCD for DTE and DCE connected to
DTE/DCE socket
J1.9
1-2
Module RTS connected to DTE/DCE socket
J1.10
1-2
Module TXD connected to DTE/DCE socket
J1.11
1-2
Module RXD connected to DTE/DCE socket
J1.12
1-2
Module CTS connected to DTE/DCE socket