C11/G2
Hardware Reference
Release r09
www.stollmann.de
Page 30 of 54
5.6 Power-up Time
The time until the C11/G2 is able to accept link requests or serial data is
about 4 seconds after power-up. This time can be reduced to approx. 1.5 seconds
by parameter change.
5.7 Wake-up Time
The time until the C11/G2 is able to process commands coming from a
sleep state / deep sleep state.
DTR
==\ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
| |
CTS
=======================\ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
| |
RX
========================[ s er i al . c ommand] - - - - - - - - - - - - - - - - - - - - - -
| |
<___________________>
180 ms (Deep sleep state)
<___________________>
120 us (Sleep state)
The module processes commands after 180ms coming from deep sleep state and
accordingly after 120us coming from sleep (power-down) state.
Serial commands can be sent directly after CTS is active(low).
Summary of Contents for BlueMod+C11/G2 Series
Page 1: ...BlueMod C11 G2 Hardware Reference Release r09...
Page 39: ...BlueMod C11 G2 Hardware Reference Release r09 www stollmann de Page 39 of 54 7 2 FCC Grant...
Page 40: ...BlueMod C11 G2 Hardware Reference Release r09 www stollmann de Page 40 of 54 7 3 IC Grant...