3.1 Incoming call
An incoming call will be shown via the ringing tone and the calling number display as
if the ISDN phone would be connected to the ISDN network directly.
To route the incoming calls to the addressed ISDN phones it is necessary to set up
the MSN of each ISDN phone. If the MSN is not configured (MSN = <empty>) in the
ISDN phone, the ISDN phone is ringing on incoming calls both on analogue line 1
and analogue line 2.
If a wrong MSN (a MSN which does not match with any MSN configured in the
TA+P2I) is configured in the ISDN phone, the ISDN phone is not ringing.
By factory the associated MSNs for the two analogue line are set to 1 (line1) and 2
(line2). For using the factory setting set up the MSN of your phones accordingly:
Phone with MSN = 1 is ringing on incoming calls on analogue line 1.
Phone with MSN = 2 is ringing on incoming calls on analogue line 2.
For experts only:
If a phone number according to the call number of the analogue lines shall be used,
you have to set up this correct MSN both in the TA+P2I and the ISDN phones.
To change the setting for the MSN for analogue line 1 please do the following:
•
Please enter the following number in on hook state of the ISDN phone
•
00000101xxx
= Set the first MSN for analogue line 1 to xxx
(factory default 1: „Dialing 000001011“)
•
Go off hook
•
Go on hook
Please proceed adequate for the second analogue line, please dial instead:
00000102xxx
= Set the first MSN for analogue line 2 to xxx (factory default 2:
„Dialing 000001022“).
Two additional MSNs can be programmed for each line accordingly by using other
dial codes (see chapter configuration).
Note: The settings can only be changed by using an ISDN phone directly
connected to the TA+P2I. Changing the settings via a ISDN PABX are not
possible, because the configuration command is not transmitted to the TA+P2I.