Chapter 4. Troubleshooting and Diagnostics
EK–MOL80–SV. B01
4–15
Table 4–3 Hardware Errors and Recovery Procedures (
continued
)
Error Code
Error Description
Recovery Procedures
(hex.)
0A
Drive 1 connection error
•
Verify if you can see other
drives
•
Switch cables (see if it stays
with the drive or cable)
•
-If indicates cable - change
cable
•
-If not, change interposer PCA
•
Change controller PCA
•
Change drive (low priority, drive
just returns a ground signal, so
would appear fine, unless the
cable was not carrying signal
0B
Drive 2 connection error
See error OA
0C
Drive 3 connection error
See error OA
0D
Drive 4 connection error
See error OA
1E
Translate motor error
•
Can not translate the picker
and/or sense that it has moved.
Picker assembly (umbilical
cable, motor, sensor)
•
If doesn't move at all – likely is
the umbilical cable
•
If it moves a little but can't
reach the side – cables good,
motor is bad
•
Got to the side, but can't sense
you did – sensor.
•
Change the controller PCA