DE300i-SWC User's Guide - Rev. A00
StorCase Technology Inc.
Appendix B - Factory-Installed Options
21
WARNING:
Be careful not to remove or disturb the carrier unit at this point.
Although the carrier is physically unlocked, the drive requires a
minimum of 15 seconds to spin down and is subject to vibration and
possible damage during this period.
3. As the unit number flashes, the Hot Swap Board monitors the activity of the SCSI
bus. When activity is no longer present, the Hot Swap Board will remove power
from the drive and then remove the device from the SCSI Bus. The unit ID number
will continue to flash during this period.
4. After a short length of time the unit display will turn from a flashing unit number to
a steady u, indicating that the device is powered down, unlocked and ready to
be removed from the receiving frame.
Carrier Installation
Follow the procedures below to install the DE300i-SWC carrier into the receiving frame
equipped with the Hot Swap option.
1. Install the Carrier into the Receiving Frame. A "u" will be present on the front panel.
2. Turn the key lock mechanism, located on the front of the receiving frame, counter
clockwise to the On position. This locks the drive into the receiving frame and
activates the Hot Swap Board. The drive will begin to spin up and the unit number
on the display will begin flashing.
3. After a short length of time the unit display will stop flashing, indicating that the
device is ready to be used.