Installation
11
Ultra320 DE100 User's Guide - Rev. A00
StorCase Technology, Inc.
Figure 9: Receiving Frame Mounting Holes
5.
Adjust the front of the receiving frame so the carrier slides freely in and out on
the receiving frame guides. The position of adjoining peripheral units may require
adjustment.
6.
Connect the I/O cable from the host adapter to the receiving frame. The Pin 1
indicator on the cable must be properly aligned. Refer to Figure 5 for the correct
Pin 1 location on connector J3.
NOTE:
Make sure that only the last SCSI device is terminated. No onboard ter-
mination is provided on the Ultra320 DE100. External termination must
be provided.
4.
With the drive carrier locked into place inside the receiving frame, install the
Ultra320 DE100 receiving frame into the drive bay in the computer or expansion
chassis. Use the appropriate guides to position the Ultra320 DE100, and fasten
it into place with the four (4) #6-32 Phillips screws provided. Figure 9 illustrates
the location of the mounting holes. Mounting holes are provided on each side
and the bottom of the receiving frame to accommodate a variety of mounting
configurations. Use the mounting holes which best suit the computer or
expansion chassis configuration.