Power
Two 1,600W load-sharing, hot-pluggable, redundant PSUs.
Nexsan E60X nominal input voltage is 200–240VAC, 47–63Hz. Cordset specification in North America is
IEC C13 to IEC C14 rated 250V/10A.
Nexsan E48X nominal input voltage is 110–240VAC, 47–63Hz. Cordset specification in North America is
IEC C13 to IEC C14 rated 250V/10A.
Typical power consumption for the Nexsan E60X is 1,059W (4.74A) for 600GB SAS drives and 684W
(3.0A) for 3TB SATA drives. Peak current is up to 15A.
Typical power consumption for the Nexsan E48X is 935W (4.2A) for 600GB SAS drives and 579W
(2.6A) for 3TB SATA drives. Peak current is up to 15A.
Cooling
Front panel: One 120mm 12V axial fan (life 40,000 hrs) per drive drawer, for a total of three.
Internal: Two double-gang 12V axial fans (life 40,000 hrs) per drive drawer, for a total of six.
PSUs: Four 12V axial fans (life 40,000 hrs) per PSU, for a total of eight.
Materials
Chassis, external: Galvanized sheet steel
Chassis, internal: Galvanized sheet steel divider plates and sub-assemblies
Fascia: ABS (blend) Thermoplastic UL 94 V.0
Environment
Ambient operating temperature: 5°C–35°C (41°F–95°F)
Minimum drawer operation temperature: 10°C (50°F)
Chapter 1: Overview
Nexsan E48X and Nexsan E60X
FRU Removal and Replacement Guide
Nexsan
9
1