- 12 -
Never remove ashes when they are hot. Store ashes in a fire-resistant and non-flammable container.
Do not store any flammable liquids near your wood-burning stove!
3.
Combustion air supply
The wood-burning stove may only be installed in rooms with a sufficient supply of combustion air. It is
guaranteed in rooms that have at least one door or window leading to the external environment that can be
opened or that are directly or indirectly interconnected with other rooms, forming a combustion air unit
with them. Such a unit only comprises rooms of one apartment or commercial unit.
THE WOOD-BURNING STOVE REQUIRES APPROX. 40 M³ OF COMBUSTION AIR PER HOUR.
In the case of new, insulated houses and mainly houses with
mechanical ventilation it is important to supply enough
combustion air. The wood-burning stove has a central connection
(from the bottom or from the back) used to supply enough air
directly to the combustion process. It means that you can provide
air via a connection pipe. The air supplied this way can be directly
controlled on the stove with a combustion air slider.
4.
Operation
4.1
Stove controller
Lever on the right (P)
Primary and secondary air is open.
Lever in the middle (S)
Primary air closed
Secondary air open
Lever on the left (0)
Primary and secondary air closed
1)
Air control slider (combustion air slider)
2)
Grill draw-bar
Primary air
is used to control combustion air from the bottom that flows through the ashpan and the grate into
the stove. Therefore, do not let the ashpan get completely filled with ashes as the ashes might prevent the supply
of combustion air.
Secondary air
controls the air quantity that is necessary to burn mainly the flammable products that are generated
in the combustion chamber during burning of wood. A certain part of secondary air that flows from the top to the
door minimizes soiling of the glass (air cleaning of the door).
As soon as the stove is heated up after the firing, close the primary air supply. Then, you can control the
combustion intensity with the secondary air only.
The
grate control
is used to open and close the grate.
The central air supply
connection for Ø 120 mm.
The temperature of the
connection may achieve up
to 80
o
C.
1
2
Summary of Contents for MAGNA SE
Page 1: ...Bedienungsanleitung User Manual Manuel d utilisation Návod k obsluze D GB F CZ MAGNA SE ...
Page 2: ......
Page 10: ... 8 Wir wünschen Ihnen viel Freude und gemütliche Stunden mit Ihrem Storch Kaminofen ...
Page 11: ... 9 ...
Page 19: ... 17 We wish you a lot of joy and pleasant hours with your Storch wood burning stove ...
Page 20: ... 18 ...
Page 29: ... 27 ...
Page 37: ... 35 ...
Page 38: ... 36 Přejeme Vám mnoho radosti a příjemně strávených hodin s Vašimi krbovými kamny Storch ...
Page 39: ... 37 Mohnweg 1 D 90613 Großhabersdorf GERMANY www storch kamine de info storch kamine de ...