145
4. Use the tool provided with the repair kit to release and
remove the outlet valve housing. Make sure that the old
o-ring, the outlet valve and the spring are removed from
the pump outlet cavity.
Installation
1. Screw the outlet valve housing into the thread. Tigh-
ten it with the supplied tool to a torque of 11 Nm.
The outlet cap prevents static electricity discharge.
Always refit the outlet cap after installing the outlet val-
ve.
2. Push the pump outlet cap back on.
Troubleshooting
Before you take the spray gun to an approved after sales
service centre, please check all the items in the trouble-
shooting table.
Problem
Cause
Remedy
The spray gun does not make
a noise when I pull the trigger
The trigger lock is active.
Release the trigger lock.
Page 129.
The status indicator shows RED when I pull
the trigger; this means that the power pack
charge is low or the power pack is cold.
Replace it with a charged power pack
and put the old power pack into the
charger, or allow the power pack to
warm up.
The status indicator flashes RED when I
pull the trigger; this means that the power
pack is too hot for use.
Allow the power pack to cool down.
The status display is not lit when I
try to use the spray gun. The power pack is
not in place, or damaged.
Install the power pack, or replace the
power pack.
Original instruction
Summary of Contents for PowerCoat FF
Page 20: ...20 Detailzeichnung Übersetzung der Originalanleitung ...
Page 50: ...50 Detailtekening Vertaling van de originele handleiding ...
Page 80: ...80 Dessin détaillé Traduction des instructions d origine ...
Page 110: ...110 Disegno dettagli Traduzione delle istruzioni originali ...
Page 140: ...140 Detailed drawing Original instruction ...
Page 170: ...170 Podrobný výkres Překlad originálu návodu ...
Page 182: ...182 ...
Page 183: ...183 ...