background image

 

Order number: 900211.002 

 

Page 1 

ST710-PCA.07 

 

 

Timer switch 

 

Order number 900211.002 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring diagram 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product description 

 

The freely programmable timer switch has two adjustable derivative timers and two elapsing tim-

ers. 

Together with the possibility of various parameters, two output contacts and two switching inputs 

will allow the employment of any applications one can think of. The timer can be started and 

stopped both with the front buttons and with the switching inputs. 

 

Front size:

 84mm x 42mm 

Panel cut-out:

 67.5mm x 31.5mm 

Tigntness:

 Front IP65 

Connector:

 plug and socket

Summary of Contents for ST710-PCA.07

Page 1: ...imers and two elapsing tim ers Together with the possibility of various parameters two output contacts and two switching inputs will allow the employment of any applications one can think of The timer can be started and stopped both with the front buttons and with the switching inputs Front size 84mm x 42mm Panel cut out 67 5mm x 31 5mm Tigntness Front IP65 Connector plug and socket ...

Page 2: ...Order number 900211 002 Page 2 ...

Page 3: ... or scroll the parameter list Key 2 DOWN By pressing this key together with the SET key you can decrease the parameter or pa rameter value or scroll the parameter list Key 3 Set Show the operating time t1 T1 can be adjusted together with the UP or DOWN key Key 4 Start Start of the timer Key 5 Stop With this key the timer can be stopped and the buzzer can be cancelled ...

Page 4: ...t the end of P15 but is active at one of the special functions P16 1 regardless of K2 Timer and display As for the operating time t1 it is possible to display the time remaining or the elapsed time see parameter P12 As for the derivate times always the respective remaining time is indicated If an acknowledgment for K2 provided see parameter P13 it is indicated until acknowledgment after the timer ...

Page 5: ...onds or by simultane ously pressing the UP and DOWN key for approx 4 seconds Para meter Function Adjustable range Standard setting Customer setting P1 Operating range t1 K1 0 0 99 9 sec 1 0 99 min 59 sec 2 0 99 Std 59 min 2 P2 Operating range TA1 TA2 0 99 9 sec 1 99 min 59 sec 0 P3 Derivative time TA1 0 see P2 0 sec P4 Derivative time TA2 0 see P2 0 sec P5 Function input E1 START 0 start with clos...

Page 6: ... respective relay is opened during the timer In the remain ing time it is closed P9 Buzzer function K2 The buzzer can be activated together with the relay K2 It sounds continuously or intermittently With the parameter setting P16 1 the buzzer sounds independently of the output K2 P10 Trigger start The start function can be triggered either by the switching input E1 and or by the key 4 This is rega...

Page 7: ...t the buzzer is linked to the final sequence stop i e to P15 If P16 1 it will sound regardless of the output K2 P17 Display after Stop and buzzer acknowledgment With P17 1 the display shows the operating time 1 after Stop or acknowledgment of the buzzer Pro Show program version The value cannot be changed Status and error messages Display Cause Remedy Flashing colon Timer was started Buzzer sounds...

Page 8: ...m for timer display colour red Two LEDs for status display of the outputs K1 and K2 Power supply 230 V 50 60 Hz power consumption max 4VA Connectors 12 pole plug and socket spacing 5 0 mm for cable up to 2 5 mm Ambient conditions Storage temperature 20 C 70 C Operating temperature 0 55 C Relative humidity max 75 without dew Weight ca 300g Enclosure Front IP65 IP00 from back Installation data Unit ...