Order number: 900211.002
Page 6
Para-
meter
Function
Adjustable range
Standard
setting
Customer
setting
P14
Operating range K2
0: 0...99.9 sec.
1: 0...99 min. 59 sec.
1
P15
Operating time K2
0... see P14
2 sec.
P16
Special functions
0: Normal function
1: both relays as K1, K2 inactive
during timer
2: both relays as K2, K1 inactive
during timer
0
P17
Display after Stop and buzzer ac-
knowledgment
0: elapsed time
1: operating time t1
0
Pro
Show program version
-----
-----
Parameter description
P1: Operating range K1
There are three operating ranges available: seconds (with 1/10 of a second), minutes/seconds, and
hours/minutes.
P5: Function input E1
“Start with closed contact” means that closing the switching input E1 starts the timer.
“Start with opened contact” means that opening the switching input E1 starts the timer.
P6: Function input E2
Same function as parameter P5, regarding the Stop function.
P7: Function output K1
P8: Function output K2
The setting “activated during timer” means the respective relay is closed (energized) during the timer. In the
remaining time it is opened (de-energized).
The setting “deactivated during timer” means the respective relay is opened during the timer. In the remain-
ing time it is closed.
P9: Buzzer function K2
The buzzer can be activated together with the relay K2. It sounds continuously or intermittently.
With the parameter setting P16 = 1 the buzzer sounds independently of the output K2.
P10: Trigger start
The start function can be triggered either by the switching input E1 and/or by the key 4.
This is regardless of the trigger of the stop function.
P11: Trigger stop
The stop function can be triggered either by the switching input E2 and/or by the key 5.
This is regardless of the trigger of the start function.
P12: Display mode operating time t1 (K1)
With the setting “countdown” the current time goes from t1 to 0.
With the setting “elapsed time” the current time goes from 0 up to t1.
P13: Stop of timer K2
0: There is no specific operating time for K2; K2 is active until pressing the STOP key
1: Same as “0”, but it’s possible to do a restart without previous stop.
2: Operating time in parameter P15 will take effect; after its expiration the timer stops.
3: Operating time in parameter P15 will take effect; after its expiration the timer restarts. The timer is now in
continuous operation until a manual stop.
P14: Operating range K2
There are two operating ranges available: seconds (with 1/10 of a second) and minutes/seconds.