Order number: 900211.002 

 

Page 6 

Para- 

meter 

Function 

Adjustable range 

Standard 

setting 

Customer 

setting 

P14 

Operating range K2 

0: 0...99.9 sec. 

1: 0...99 min. 59 sec. 

 

 

P15 

Operating time K2 

0... see P14 

2 sec. 

 

P16 

Special functions 

0: Normal function 

1: both relays as K1, K2 inactive 

during timer 

2: both relays as K2, K1 inactive 

during timer 

 

P17 

Display after Stop and buzzer ac-

knowledgment 

0: elapsed time 

1: operating time t1 

 

Pro 

Show program version 

----- 

----- 

 

 

 

 

Parameter description 

 

P1: Operating range K1 

There are three operating ranges available: seconds (with 1/10 of a second), minutes/seconds, and 

hours/minutes.  

 

P5: Function input E1 

“Start with closed contact” means that closing the switching input E1 starts the timer. 

“Start with opened contact” means that opening the switching input E1 starts the timer. 

 

P6: Function input E2 

Same function as parameter P5, regarding the Stop function. 

 

P7: Function output K1 

P8: Function output K2 

The setting “activated during timer” means the respective relay is closed (energized) during the timer. In the 

remaining time it is opened (de-energized). 

The setting “deactivated during timer” means the respective relay is opened during the timer. In the remain-

ing time it is closed. 

 

P9: Buzzer function K2 

The buzzer can be activated together with the relay K2. It sounds continuously or intermittently. 

With the parameter setting P16 = 1 the buzzer sounds independently of the output K2. 

 

P10: Trigger start 

The start function can be triggered either by the switching input E1 and/or by the key 4. 

This is regardless of the trigger of the stop function. 

 

P11: Trigger stop 

The stop function can be triggered either by the switching input E2 and/or by the key 5. 

This is regardless of the trigger of the start function. 

 

P12: Display mode operating time t1 (K1) 

With the setting “countdown” the current time goes from t1 to 0. 

With the setting “elapsed time” the current time goes from 0 up to t1. 

 

P13: Stop of timer K2 

0: There is no specific operating time for K2; K2 is active until pressing the STOP key 

1: Same as “0”, but it’s possible to do a restart without previous stop. 

2: Operating time in parameter P15 will take effect; after its expiration the timer stops. 

3: Operating time in parameter P15 will take effect; after its expiration the timer restarts. The timer is now in 

continuous operation until a manual stop. 

 

P14: Operating range K2 

There are two operating ranges available: seconds (with 1/10 of a second) and minutes/seconds. 

 

Summary of Contents for ST710-PCA.07

Page 1: ...imers and two elapsing tim ers Together with the possibility of various parameters two output contacts and two switching inputs will allow the employment of any applications one can think of The timer can be started and stopped both with the front buttons and with the switching inputs Front size 84mm x 42mm Panel cut out 67 5mm x 31 5mm Tigntness Front IP65 Connector plug and socket ...

Page 2: ...Order number 900211 002 Page 2 ...

Page 3: ... or scroll the parameter list Key 2 DOWN By pressing this key together with the SET key you can decrease the parameter or pa rameter value or scroll the parameter list Key 3 Set Show the operating time t1 T1 can be adjusted together with the UP or DOWN key Key 4 Start Start of the timer Key 5 Stop With this key the timer can be stopped and the buzzer can be cancelled ...

Page 4: ...t the end of P15 but is active at one of the special functions P16 1 regardless of K2 Timer and display As for the operating time t1 it is possible to display the time remaining or the elapsed time see parameter P12 As for the derivate times always the respective remaining time is indicated If an acknowledgment for K2 provided see parameter P13 it is indicated until acknowledgment after the timer ...

Page 5: ...onds or by simultane ously pressing the UP and DOWN key for approx 4 seconds Para meter Function Adjustable range Standard setting Customer setting P1 Operating range t1 K1 0 0 99 9 sec 1 0 99 min 59 sec 2 0 99 Std 59 min 2 P2 Operating range TA1 TA2 0 99 9 sec 1 99 min 59 sec 0 P3 Derivative time TA1 0 see P2 0 sec P4 Derivative time TA2 0 see P2 0 sec P5 Function input E1 START 0 start with clos...

Page 6: ... respective relay is opened during the timer In the remain ing time it is closed P9 Buzzer function K2 The buzzer can be activated together with the relay K2 It sounds continuously or intermittently With the parameter setting P16 1 the buzzer sounds independently of the output K2 P10 Trigger start The start function can be triggered either by the switching input E1 and or by the key 4 This is rega...

Page 7: ...t the buzzer is linked to the final sequence stop i e to P15 If P16 1 it will sound regardless of the output K2 P17 Display after Stop and buzzer acknowledgment With P17 1 the display shows the operating time 1 after Stop or acknowledgment of the buzzer Pro Show program version The value cannot be changed Status and error messages Display Cause Remedy Flashing colon Timer was started Buzzer sounds...

Page 8: ...m for timer display colour red Two LEDs for status display of the outputs K1 and K2 Power supply 230 V 50 60 Hz power consumption max 4VA Connectors 12 pole plug and socket spacing 5 0 mm for cable up to 2 5 mm Ambient conditions Storage temperature 20 C 70 C Operating temperature 0 55 C Relative humidity max 75 without dew Weight ca 300g Enclosure Front IP65 IP00 from back Installation data Unit ...

Reviews: