background image

StormPro

® 

BA

 

Series

Sump Pump

OPERATION MANUAL

Dated: 02/15/2013

Document Name: StormPro_BASeries_OM

Page 6 of 8

Register your product at www.sumpro.com

n

otes

Summary of Contents for BA Series

Page 1: ...als or objects WARNING This sign warns the operator that the failure to follow an instruction may damage the pump and or the system Limitations This pump series is suitable to pump water and also can be used both for permanent and temporary installation The pump can be placed in a sump pit that means it could pump rain water containing suspended solid particles no larger than in diameter Total Dyn...

Page 2: ... 4 A permanent ground connection from pump to the grounding bar at the service panel is mandatory StormPro sump pumps come with a grounding conductor and a grounding type attachment plug Do not connect pump to a power supply until permanently grounded For maximum safety connect pump to a circuit equipped with a fault interrupter device when you position the pump s grounding wire 5 Voltage of power...

Page 3: ... that the electric system is grounded in accordance with the law in force 2 The plug and connections should be protected from water splashes Before using the pump always inspect it visually especially power cable and plug 3 Do not use the pump if it is damaged 4 If the pump is damaged have it inspected by an authorized service center only 5 Make sure that electric connections are protected from in...

Page 4: ...eck the following 1 Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Drill a 1 8 inch hole into PVC discharge pipe 2 Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pump Inlet holes in pump base are clogged Remove pump and clean the strainer and openings 3 Impeller or volute opening...

Page 5: ...ddress City Purchased From Installed By Phone Date State Zip Warranty VOID if The following may cause severe damage to pump and will void the warranty 1 Using an extension cord 2 Power cord has been cut or altered 3 Cutting off the ground pin or using an adapter fitting 4 Working on pump or switch while plugged in 5 Removing motor housing unscrewing impeller or otherwise removing impeller seal 6 R...

Page 6: ...StormPro BASeries Sump Pump OPERATION MANUAL Dated 02 15 2013 Document Name StormPro_BASeries_OM Page 6 of 8 Register your product at www sumpro com Notes ...

Page 7: ...StormPro BASeries Sump Pump OPERATION MANUAL Dated 02 15 2013 Document Name StormPro_BASeries_OM Page 7 of 8 Register your product at www sumpro com Notes ...

Page 8: ... correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3 Process of Claims and Repairs Metro...

Reviews: