Maintenance
Removing and Cleaning the Jet Plate
Page 17
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
Removing and Cleaning the Jet Plate
Remove and clean the jet plate to clear blocked nozzles. To access the jet plate, you need to
remove the cover (see
Removing the Jet Plate
To remove the jet plate:
).
2. Insert a long-neck, 7/16 inch (11 mm) socket wrench into the jet plate.
Figure 10: Loosening the jet plate
3. Loosen the nuts by turning the socket wrench half a turn.
4. Using a 1/4 inch (6 mm) socket wrench or screwdriver, loosen the hose clamp.
5. Carefully lift off the jet plate and make sure it is clear of the level switch.
When you remove the jet plate, the cleaning solution is likely to drip from it. Be
careful that it does not drip on you.