Introduction
The CSIIP CleanStation uses agitation and alkaline cleaning solution to rapidly dissolve soluble
Support material from printed parts and models.
About this Guide
The information and requirements provided in this document ensure proper operation of the
cleaning station. If you have any questions about the information in this document, contact your
Stratasys service provider.
For More Information
For more information about Stratasys, its technologies, products, and application methods, visit
http://www.stratasys.com
. If you have any questions about the information presented in this
document, or if you have any comments or suggestions for future editions, please send a
message to
c-support@stratasys.com
.
Safety Guidelines
The following general guidelines, together with the instructions provided throughout this guide,
ensure user safety while operating and maintaining the CSIIP CleanStation.
•
Never operate the cleaning station while the cover is open.
•
The power cable should be connected at an easily accessible electric socket.
•
Make sure that the power cable does not become taut.
•
A VAC ground fault interrupter (GFI, or Residual Current Device - RCD) should be used.
•
Only operate the cleaning station when wearing protective gloves, safety goggles and a
protective mask.
•
Make sure that the room is properly ventilated. The ventilation system should change the
air at least four times every hour.
•
Remove parts with the supplied basket or with steel or plastic tongs. Do not use aluminum
tongs to remove parts from the cleaning solution.
•
Never move the unit when there is liquid in the tank.
•
Placing parts in the tank raises the liquid level. Monitor the liquid level of the tank to prevent
overflowing.
Important:
If the system is not operated as specified, the user's safety might be compromised!