Operating Instructions
Draining the Tank
Page 14
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
Draining the Tank Using the Drain Pump
To drain the tank using the drain pump:
1. Close the tank cover.
2. Put on gloves, mask, and safety goggles.
3. If local regulations allow, drain the solution into a drainage pipe. Otherwise, drain the tank
into a 16-gallon (60-liter) container.
4. Make sure that the drain hose is securely in place.
5. Open the operator panel.
6. Set the CONTROL VALVE to DRAIN TANK.
7. Set the SELECTOR to DRAIN TANK.
8. When liquid stops flowing, stop the pump by setting the SELECTOR to OFF.
9. Check that the tank is empty. If it is not, see
“Emptying Excess Liquid from the Tank”
below.
Warning: Chemical Hazard.
The liquid drains out quickly and you might need to hold the hose to prevent it from
splashing.
Caution:
Running the pump without liquid can result in damage. Do not leave the unit
unattended while draining. Turn the SELECTOR to OFF as soon as the tank is
completely drained.