Emptying Excess Liquid from the Tank
Occasionally, the tank does not completely drain. If this happens, remove excess liquid and
residue.
To empty excess liquid and residue from the tank:
1. Add water to the tank to help the liquid flow more freely through the filter.
2. Use the pump (see
“Draining the Tank Using the Drain Pump” (page 14)
).
3. If there is still excess liquid or residue in the tank, use a spatula to push the liquid into the
filter.
Figure 8: Pushing excess liquid into the filter
If the filter is clogged, see
“Cleaning the Filter” (page 21)
.
Caution:
Dispose of the liquid and residue according to local regulations.
After emptying the tank, and before refilling it, flush the system with fresh water (see