Maintenance
Cleaning the Filter
Page 21
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
Re-attaching the Jet-Plate Cover
To re-attach the cover:
1. Position the cover on the unit, making sure that it is straight.
2. Using a 7/16 inch (11 mm) socket wrench, tighten the nuts on both sides of the cover (see
Cleaning the Filter
If the liquid does not drain properly from the tank, the filter might be blocked.
To clean the filter:
1. Drain the tank completely (see
2. Using a 3 mm (1/8 inch) hex (Allen) key, remove the four screws securing the filter.
Figure 15: Filter
3. Clean the filter under running water.
4. Re-attach the filter.
After performing maintenance on the jet plate and the level sensor, it is recommended
to check that the jets function properly (see
).
Warning: Sharp Edges.
The edges of the filter might be sharp. Use caution when cleaning it.