Installing and Using the Blood Vessel Cleaning Apparatus Kit (Optional) Inserting the BVCA Cleaning Fixture
Page 32
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
4. Lower the BVCA cleaning fixture into the cleaning tank.
Figure 27: Cleaning fixture placed in tank
5. Place the overflow tube outside of the cleaning fixture, as shown in
.
6. Push and hold in the button on the water supply connector, shown in
, while
pushing the manifold down to connect the water supply pipes to the manifold.
7. Release the button on the water supply connector, and pull up slightly on the manifold to
verify that the manifold is connected.
You can install the BVCA cleaning fixture with the elbows and tubes connected or
without, whichever is easiest.
Pressure
gauge
Manifold
Water supply
connector
Pressure
regulator
Overflow tube