CleanStation™ CSIIP Installation Guide
DOC-03204 Rev. B
14
3.6 Leveling the CleanStation™ CSIIP
1. Turn the leveling feet adjustment gears until the unit rests on its leveling feet.
2. Place a spirit level on the top cover oriented from back to front.
3. Adjust the leveling feet as shown below until the bubble indicates that the unit
is level.
Figure 13 Leveling the unit—front to back
4. Orient spirit level from left to right and repeat step 3.
Figure 14 Leveling the unit—left to right
5. After the unit is level, make sure that it is not resting on any of its wheels.