CleanStation CSIIP Site Preparation Guide
DOC-03202 Rev. A
7
4 Site Requirements
The following factors should be considered when choosing a suitable location for
the CSIIP:
• Clearance around and above the CSIIP to enable convenient access and
servicing
• Proximity to a water outlet and drain
To avoid water damage to CSIIP, install CSIIP in another room or at least
5 meters (16.5 feet) away from the CSIIP.
• Proximity to an area where models can dry after CSIIP treatment
4.1 Positioning / Clearance
For proper ventilation, place the CSIIP in a location with a minimum of 40 cm
(16 inches) around the CSIIP at all times.
To enable easy access, allow approximately 1.5 meters (59 in) in front of the
CSIIP.
4.2 Water and Drain Connections
The CSIIP is supplied with a water inlet hose that is 1.8 m (6 ft) long, with a
19 mm (3/4 inch) connector for connecting to a water supply tap. It is the
customer's responsibility to ensure that there is a water tap near the CSIIP
installation location.
The waste water/solution from the unit should empty into the building’s drainage
system. The customer must prepare a suitable drain near the unit. It is
recommended that you locate the drain pipe behind the CSIIP.
Dispose of the waste water/solution according to local regulations. Prepare
the waste disposal system accordingly.
The drain hose supplied with the CSIIP is 19 mm (3/4 inch) inner diameter
(25 mm/1 inch outer diameter) and 1.8 m (6 ft) long. The CSIIP can drain the
waste water/solution via gravity or a built-in pump. If using the pump, the
customer must verify that the drain hose is secured to the drain.
4.3 Floor
The customer must verify that the floor is stable and able to bear the load of the
CSIIP filled with water/solution and the models.
Water is likely to drip from the models after cleaning. Therefore, it is
recommended that the floor around the CSIIP have a non-slip surface.