background image

DOC-01121 Rev. A

DT3 CLEANSTATION

USER GUIDE

Summary of Contents for CleanStation DT3

Page 1: ...DOC 01121 Rev A DT3 CLEANSTATION USER GUIDE...

Page 2: ...The specifications on which this document is based are subject to change without notice No part of this book may be reproduced in any form or by any means nor stored in a database or retrieval system...

Page 3: ...on 9 5 4 Using the Control Panel 9 5 4 1 Setting the Timer 10 5 4 2 Starting the Cleaning Cycle 10 5 4 3 Stopping the Cleaning Cycle 10 5 5 Removing Printed Models 10 5 6 Draining the Tank 11 5 6 1 Dr...

Page 4: ...ation The customer is responsible for preparing the site as described in this document If you have any questions about the information in this document contact your Stratasys representative 1 2 For Mo...

Page 5: ...10 Liquid Capacity Liters Gallons 22 7 6 Weight Kilograms Pounds Empty 28 6 63 Full 45 4 up to 100 including models Operating Temperature Celsius Fahrenheit 4 4 C to 85 C 40 F to 185 F Electrical Spe...

Page 6: ...DT3 CleanStation Never move the DT3 CleanStation when there is liquid in the tank Placing parts in the tank raises the liquid level Monitor the liquid level of the tank to prevent overflowing 3 1 Alka...

Page 7: ...comes tight or disconnects from the power socket at least 15 cm 6 inches clearance on each side room temperature between 18 C and 25 C 65 F 77 F Recommendations a non slip floor because water may drip...

Page 8: ...approximately 23 liters 6 gallons Warning Adding too much water to the tank will cause it to overflow Fill the tank until at least 2 54 cm 1 inch below the top of the tank If you fill the tank more t...

Page 9: ...Cleaning Cycle on the next page 5 4 Using the Control Panel You use the control panel to operate the DT3 CleanStation Figure 3 Control panel Warning Do not change the factory default settings Doing s...

Page 10: ...le press the infinity and down buttons 5 4 3 Stopping the Cleaning Cycle The DT3 CleanStation stops automatically when the timer counts down to zero To manually stop the cleaning cycle press the infin...

Page 11: ...ose and drainage valve 4 When the tank is empty close the drainage valve 5 6 2 Draining Alkaline Cleaning Solution Before handling the alkaline solution read Alkaline Cleaning Solution Safety Instruct...

Page 12: ...gnificant decrease in water circulation there might be a build up of printing material blocking the pump suction strainer or manifold 6 2 1 Cleaning the Pump Suction Strainer Warning Always wear neopr...

Page 13: ...ing it 5 Dry the jet plate Figure 5 Cleaning the suction strainer If you find a significant amount of material deposits in the suction strainer it might not be necessary to also clean the manifold If...

Page 14: ...uts 3 Completely remove the pipe clamps and manifold 4 Remove the material deposits blocking the jets by either pulling it through the holes or by flushing the manifold with water Figure 6 Cleaning th...

Page 15: ...disconnect the DT3 CleanStation from the wall socket and keep the power cable in view so that it is not accidentally plugged back in To check and replace the fuse 1 Disconnect the unit from the wall...

Page 16: ...ck that the suction strainer and the manifold jets are clear of material deposits see Maintenance on page 12 7 3 Error Messages on the Control Panel If an error is displayed such as Err4 or Err5 conta...

Page 17: ...www stratasys com ___ THE 3D PRINTING SOLUTIONS COMPANY...

Reviews: