background image

DOC-01207 Rev. A

Page 15

WaterJet Support Table/Counter Specifications

4 Site Requirements

The

 

following

 

factors

 

should

 

be

 

considered

 

when

 

choosing

 

a

 

suitable

 

location

 

for

 

the

 

WaterJet

 

unit:

• Type

 

of

 

configuration:

 

countertop

 

or

 

floor

• Proximity

 

to

 

the

 

Stratasys

 

3D

 

printer.

To

 

avoid

 

water

 

damage

 

to

 

the

 

printer,

 

install

 

the

 

WaterJet

 

in

 

another

 

room

 

or

 

at

 

least

 

5

 

meters

 

(16.5

 

feet)

 

away

 

from

 

the

 

printer.

• Proximity

 

to

 

an

 

area

 

where

 

models

 

can

 

be

 

soaked

 

in

 

caustic

 

soda

 

(sodium

 

hydroxide),

 

and

 

where

 

they

 

can

 

dry

 

after

 

WaterJet

 

treatment.

4.1 WaterJet Support Table/Counter Specifications

The

 

recommended

 

height

 

of

 

the

 

table/counter

 

is

 

80

 

cm

 

(31

 

inches).

 

This

 

establishes

 

a

 

height

 

of

 

120

 

cm

 

(47.2

 

inches)

 

at

 

arm

 

level

 

for

 

the

 

average

 

person.

The

 

support

 

table

 

or

 

counter

 

must

 

be

 

sturdy

 

capable

 

of

 

carrying

 

a

 

load

 

of

 

at

 

least

 

30

 

kg

 

(66

 

lb).

 

The

 

table

 

must

 

be

 

level.

4.2 Water Supply

The

 

WaterJet

 

system

 

requires

 

a

 

connection

 

to

 

the

 

regular

 

water

 

supply.

The

 

customer

 

must

 

supply

 

a

 

suitable

 

water

 

tap.

 

The

 

water

 

tap

 

should

 

be

 

located

 

next

 

to,

 

or

 

in

 

back

 

of

 

the

 

water

 

pump.

 

Warning:

Two people are required to lift the WaterJet unit onto the table.

Summary of Contents for Objet WaterJet

Page 1: ...Stratasys Confidential and Proprietary Information Objet Desktop WaterJet Site Preparation Guide DOC 01207 Rev A Sept 2012 Stratasys Ltd ...

Page 2: ......

Page 3: ...based are subject to change without notice No part of this book may be reproduced in any form or by any means nor stored in a database or retrieval system without prior permission in writing from Stratasys Ltd If this document is distributed as a PDF file you may print it for internal use DOC 01207 Revision A Sept 2012 Trademarks The following are registered trademarks of Stratasys Ltd Stratasys O...

Page 4: ......

Page 5: ...nformation and Responsibility 9 2 2 Shipping Pallets 9 3 Physical Description 3 1 Configuration 11 3 2 Size and Weight 12 3 3 WaterJet Unit Model Capacity 13 4 Site Requirements 4 1 WaterJet Support Table Counter Specifications 15 4 2 Water Supply 15 4 3 Drain 17 4 4 Floor 18 4 5 Power 18 5 Technical Specifications 6 Site Preparation Checklist ...

Page 6: ......

Page 7: ...tasys its technology products and consumables and for application information If you have any questions about the information presented in this document or if you have any comments or suggestions for future editions please send a message to c support stratasys com 1 2 Terms Used in This Guide Important Since preparation of the site must be completed before the installation date you must fax the ch...

Page 8: ......

Page 9: ... delivery instructions The customer is also responsible for transporting the system to a suitably prepared installation site 2 2 Shipping Pallets The WaterJet system is delivered to the site on a wooden pallet The approximate size and weight of the pallet are shown in Table 1 Weight gross weight of the packed crate Important Equipment should be unpacked and installed by authorized Stratasys repres...

Page 10: ......

Page 11: ... WaterJet system consists of following main components a WaterJet unit cabinet and stand b water pressure pump c metal base d stand extensions Figure 3 1 WaterJet components The water pressure pump supplied with the WaterJet may differ from the water pressure pump shown above b c d a ...

Page 12: ...inches The following figure shows the WaterJet unit installed on a table Figure 3 2 WaterJet unit installed on a table Table 2 WaterJet and water pressure pump dimensions and weights Unit W H D cm W H D in Weight WaterJet with table stand 58 75 70 22 8 29 5 27 5 25 6 kg 56 3 lb WaterJet with floor stand 58 155 70 22 8 61 27 5 30 kg 66 lb Water Pressure Pump 220 240 V 29 5 55 6 24 11 6 21 9 9 4 9 k...

Page 13: ...ity WaterJet can clean models that have the following maximum dimensions The WaterJet is adequate for cleaning printed models of typical size Some Stratasys printers are capable of printing models whose dimensions are greater than those specified in Table 3 The WaterJet is not suitable for cleaning very large models Table 3 Maximum model dimensions W H D cm W H D in Maximum model size 30 25 20 11 ...

Page 14: ......

Page 15: ...da sodium hydroxide and where they can dry after WaterJet treatment 4 1 WaterJet Support Table Counter Specifications The recommended height of the table counter is 80 cm 31 inches This establishes a height of 120 cm 47 2 inches at arm level for the average person The support table or counter must be sturdy capable of carrying a load of at least 30 kg 66 lb The table must be level 4 2 Water Supply...

Page 16: ...he water pressure pump Figure 4 5 Garden hose hose adapters and hose clamps The water pressure pump can be placed up to 3 meters 10 feet from the water tap If you need to place the water pressure pump farther away from the water tap install a longer garden hose not supplied Using the pressure hose and electrical cable supplied with the pump you can place the water pressure pump up to 3 meters 10 f...

Page 17: ... system Therefore you must prepare a suitable drain near the unit It is recommended that you locate the drain pipe behind the WaterJet unit and below the drain outlet on the WaterJet The WaterJet unit comes equipped with a drain hose approximately 3 meters 10 feet in length You can connect the hose to a standard drain pipe with a diameter of 3 9 centimeters 1 5 inches Power to Pump Water In Pressu...

Page 18: ...els 4 5 Power Wall outlet An electrical outlet must be available near the WaterJet unit preferably in back of the unit to reduce the chances of water spraying on the outlet The wall outlet must have or be connected to a residual current device RCD ground current leakage detector that protects from a leakage of more than 30mA Circuit breaker The electrical circuit must be protected by a circuit bre...

Page 19: ...ca and Japan an IEC 320 C13 to 5 15P 15A 120 V power cable is supplied Figure 4 8 Power cable for North America and Japan example 4 5 1 Grounding The WaterJet unit is grounded through the AC plug Make sure that the ground connector in the ground fault protection wall outlet or on the circuit is properly grounded in accordance with your local electrical codes ...

Page 20: ......

Page 21: ... foot switch Other Internal low energy light Support waste collector Water Pressure Pump Water intake Standard water tap with hose connection Minimum intake water pressure 1 atm Maximum intake water temperature 40 C 104 F Water consumption Less than 10 liters min at 2800 RPM Noise level 85 88 dB acoustic protection required WaterJet Water Pressure Pump Electrical rating 220 240 volt 50 Hz 10A or 1...

Page 22: ......

Page 23: ... _______________________________________________________________ Address ______________________________________________________________________ _________________________________________________________________________ Phone No ___________________________Fax No _______________________________ E mail ____________________________________ Customer full name _____________________________________ Custom...

Reviews: