Objet WaterJet Site Preparation Guide
Site Requirements
Alternatively,
you
can
connect
an
extension
to
the
WaterJet
drain
hose
and
run
it
to
a
nearby
drain,
as
shown
in
Figure 4–7
Drain configurations (examples)
4.4 Floor
It
is
recommended
that
the
floor
around
the
WaterJet
unit
have
a
non
‐
slip
surface
because
water
may
drip
from
cleaned
models.
4.5 Power
• Wall
outlet
An
electrical
outlet
must
be
available
near
the
WaterJet
unit,
preferably
in
back
of
the
unit,
to
reduce
the
chances
of
water
spraying
on
the
outlet.
The
wall
outlet
must
have
(or
be
connected
to)
a
residual
current
device
(RCD)—
ground
current
‐
leakage
detector—that
protects
from
a
leakage
of
more
than
30mA.
• Circuit
breaker
The
electrical
circuit
must
be
protected
by
a
circuit
breaker
with
the
specifications
shown
in
the
following
table.
Table 4: Circuit breaker specifications
Voltage
Circuit Breaker
100 VAC
15 Amps
110–120 VAC
15 Amps
220–240 VAC
10 Amps