Number of Collectors

2

3

DN 15 pipes

40m

30m

Table 13

Water Supply

Approved pressure limiting valves rated at 500kPa are 

required if the mains water supply pressure exceeds 

500kPa.

The gas booster will not achieve the maximum rated flow 

if the mains water supply pressure is below the minimum 
supply pressure specified for the gas booster in Table 7 

“Gas Boosters Specifications”. The system will operate at 

lower pressures but will deliver hot water at lower flow 
rates.

Water chemistry and impurity limits are specified under 

“Water Quality” in the “Important Information” section 

of these instructions. Metropolitan water supplies 
generally meet these requirements. Please contact the 
relevant water supply authority or have the water tested 
if uncertain about the water supply quality.

If necessary, a suitable filter or water softener should be 
fitted in the mains water supply to achieve the required 
water quality.

For locations with high sediment levels in the water 
supply, the hot water storage tank should be flushed at 
regular intervals. Stratco recommend that a drain cock 
is fitted at the cold water inlet to the hot water storage 
tank.

Water Pipes, Valves & Fittings

All hot water pipes must be insulated with thermal 

lagging such as Polyethylene foam to reduce heat loss 
and maximise performance of the solar hot water heating 

system.

All pipe sizes should conform to AS/NZS 3500 except 

collector flow and return pipes.

Solar collector flow and return pipes should be 15mm 
copper tube to withstand the high pressures and 
temperatures that occur. Maximum recommended total 
lengths for the cold water flow and hot water return 
pipes are shown in Table 13.

The pressure and temperature relief (P&TR) valve is a 

safety device and must be fitted to the hot water storage 
tank. The P&TR valve supplied is rated at 10.0kW, 

which must exceed the thermal load applied to the hot 
water storage tank. For gas boosted solar hot water 
heater systems, the thermal load is applied by the solar 

collectors only. The gas booster does not apply thermal 
load to the hot water storage tank.

A cold water expansion control valve (ECV) rated at 

700kPa must be fitted to the cold water supply of the hot 

water storage tank. This will reduce hot water discharge 
resulting in wear of the P&TR valve.

Approved pressure limiting valves rated at 500kPa must 

be fitted if the mains water supply pressure exceeds 

500kPa.

A combination non-return/isolating valve and strainer is 

fitted to the cold water supply of the hot water storage 
tank.

Gas boosters for Stratco Solarcore

TM

 hot water heating 

systems are preset to deliver hot water at 70°C in 
accordance with plumbing regulations. A temperature 

limiting device, such as thermostatic mixing or tempering 
valves, must be fitted to limit the hot water temperature 

For vitreous enamel hot water storage tanks, allow a 
clearance of one cylinder height above the hot water 
storage tank to allow inspection and replacement of the 
sacrificial anode. 

Gas Booster Location

The gas booster is designed for outdoor installation only, 
and must be located in a position where wind and natural 
convection will disperse gas leakage and combustion 
products.

The gas booster must be mounted on a vertical surface 
with the water and gas connections underneath. In most 
installations the gas booster is mounted directly on the 
hot water storage tank.

If the gas booster is not mounted on the hot water 
storage tank, ensure that the wall or structure on which 
it will be mounted is capable of supporting the weight 
of the gas booster and associated plumbing. The weight 
of the gas booster models is specified in Table 7 “Gas 
Boosters Specifications”.

The location of the gas booster terminal flue must be in 
accordance with AS 5601 Figure 5.3.

Refer to AS 5601 for specific requirements in relation to 
gas boosters installed on elevated structures or under 
floors.

The gas booster will require a gas supply as outlined 
in  the “Gas Supply” section of these instructions and a 
240V, 10A earthed weather proof power point.

Gas Supply

The gas meter and regulator must be rated for the 
maximum flow of the gas booster in addition to all 
other gas appliances on the premises. Please refer to 
the manufacturer’s instructions for the gas booster to 
determine maximum gas consumption and required gas 
pressure. 

It is the installers responsibility to ensure gas meter, 
regulator and pipework are functional, sized correctly 
and rectify as necessary.

Gas pipe sizing must conform to the sizing chart in AS 
5601. If pipe sizes are not sufficient, the gas booster will 
not achieve full heating performance.

An approved full flow isolation valve and disconnection 
union must be fitted to the gas inlet of the gas booster.

Summary of Contents for Solarcore G21520L666VE

Page 1: ...al Occupational Health Safety regulations Wind Regions Covered Flat Mount Kit Region A N1 N2 N3 Region B N1 N2 N3 N4 Checked to AS NZS 1170 2 2002 and AS4055 2006 Tilt Mount Region A N1 N2 N3 Maximum...

Page 2: ...e tank During extended absences in summer it is advisable to cover the solar collector to avoid overheating the system and excessive dumping of hot water from the P TR valve Hydrogen Gas Warning For v...

Page 3: ...ect heat from sunlight during cool windy or even overcast weather The heat is rapidly transferred to water passing through copper pipes inside the evacuated glass tubes A pump circulates the heated wa...

Page 4: ...NUT Qty 4 or 6 ANGLE BRACE M10 NUT Qty n a M10 SOCKET BOLT Qty n a M10 WASHER Qty n a ANGLE BRACE SHORT FRAME RAIL RAIL NUT TILT BRACKET CGI ROOF BRACKET FLAT ROOF BRACKET TILT MOUNT CIRCULATION PUMP...

Page 5: ...Litre Number of Collectors 2 3 3 Continuous Flow Gas Boost Size L min 20 26 20 26 20 26 Weight Cylinder Empty kg 88 95 Connections All connections parallel pipe threads of whitworth form Solar Flow a...

Page 6: ...Up Time 45 C Rise 2hrs 55min 4hrs 40min Recovery Rate Litres per Hour 45 C Rise 69 69 Weight Cylinder Empty kg 88 103 Connections All connections parallel pipe threads of whitworth form Solar Flow an...

Page 7: ...SX 65 C 65 C Switch on Temp Reheating TO 40 C not used N A Switch off Temp Reheating TF 40 C not used N A Freeze Protection Function Collector AF 1 freeze prot function active N A Operating Mode MM 4...

Page 8: ...f true North is acceptable Mounting the solar collector on a North East or North West facing roof will only reduce solar collector efficiency by approximately 5 Solar Collector Inclination The ideal i...

Page 9: ...e hook on the bottom stainless steel straps with the markings Fasten the bottom stainless steel straps to the roof battens using two hex head self drilling wood or metal screws as shown in Figure 6 It...

Page 10: ...er and seal the opening of the orifice with a small amount of silicon Run the hot temperature sensor leads under a tile into the roof space and down to the solar pump controller but do not connect at...

Page 11: ...In Region B Terrain Category 1 where roof mount tilt kits are attached to steel framing the steel framing rafter spacing is limited to maximum 1200mm Regulations OH S Before starting construction and...

Page 12: ...he batten and roof sheet using two M6 TS self drilling screws as noted in the Layout Rules within this section of these instructions A protective anti corrosion barrier must be installed between dissi...

Page 13: ...and second frame rail at one end to stop the frame from tipping thereby keeping a square alignment Upright Rail Positioning Position a series of roof brackets corresponding to the front row at the di...

Page 14: ...led distance is to be measured between neighbouring upright rails on the outer of the roof mount tilt kit frame Figure 18 This measurement is used to determine the cut length required of the angle bra...

Page 15: ...de of the solar collector panel when tightening the rail nuts When all inlet and outlet nuts are threaded firmly and the solar collector panels are in the desired position tightly fasten the rail nuts...

Page 16: ...hed power point IMPORTANT NOTE The controller is factory programmed to the correct settings These settings must not be altered Toensurefrostprotectionthepowermustremainconnected to the electronic cont...

Page 17: ...Location The hot water storage tank should be located as close as possible to the most frequently used hot water outlets to minimise water wastage and heat loss Also consider that the solar collector...

Page 18: ...n wear of the P TR valve Approved pressure limiting valves rated at 500kPa must be fitted if the mains water supply pressure exceeds 500kPa A combination non return isolating valve and strainer is fit...

Page 19: ...pansion control valve and tee to the cold water inlet connection at the bottom of the hot water storage tank A pressure limiting valve is required if the water supply pressure exceeds 500kPa Fit the s...

Page 20: ...8 Solar collectors Supplied by Installer 2 DN15 Solar return pipe insulation connections 5 DN20 copper tube 20mm thick insulation connections 6 Gas supply pipe Isolating valve Disconnection union fitt...

Page 21: ...external installation For external installation the hot water storage tank should be mounted on a concrete base at least 50 mm thick in accordance with AS NZS 3500 4 clause 4 5 3 or on well seasoned...

Page 22: ...connection details The installation of the electric boosted Stratco SolarcoreTM hot water system is now complete Follow the commissioning procedure carefully to ensure the electric boosted solar hot...

Page 23: ...e limiting valve 9 DN15 Water supply pipe connections 10 DN15 Solar flow pipe insulation connections 17 Tempering valve 18 Hot water non return valve 19 240V Power Supplied in Kit 1 Hot temperature se...

Page 24: ...red green to show the pump is running Press the button to exit the settings menue until TC and TS are shown in the display OUTDOOR CONTROLLER Press and hold the pump button The circulating pump shoul...

Page 25: ...he power points for the electronic controller circulating pump or the water supply For gas boosted systems switch off the power points for the gas booster To ensure frost protection do not switch off...

Page 26: ...nk Check mains water isolating valve to inlet of hot water storage tank is open Check mains water isolating valve at water meter is open Check water flow at a cold water tap and contact the water supp...

Page 27: ...the solar collector should be checked for vacuum every 5 years This is indicated by a silver coating at the bottom of the glass tube If the bottom of the glass tube has turned white or clear the glas...

Page 28: ...d systems or isolate power supply to the heating element at the mains for electric boosted systems Close the isolating valve on the cold water supply to the hot water storage tank Disconnect the elbow...

Reviews: