50
Examples D and E maximum pipe lengths
Example D (C33)
Boiler Type
→
S-CBX 85 S-CBX
105
S-CBX
125
S-CBX 155
Diameter concentric pipe [mm] 100/150
100/150
100/150
NOT
POSSIBLE
Concentric roof terminal [mm] 100/150
100/150
100/150
Maximum pipe length [m]
includes: 2 bends 90°
2 bends 45°
roof terminal
12.4
-
-
Example E (C13)
Boiler Type
→
S-CBX 85 S-CBX
105
S-CBX
125
S-CBX 155
Diameter concentric pipe [mm] 100/150
100/150
100/150
NOT
POSSIBLE
Concentric wall terminal [mm] 100/150
100/150
100/150
Maximum pipe length [m]
includes: 1 bend 90°
wall terminal
36.8
18.4
3.5