background image

Summary of Contents for Super HR

Page 1: ...OPERATING INSTRUCTIONS 8G 52 20 01 09 02 We reserve the right to make changes Reliability Innovations ...

Page 2: ......

Page 3: ...ram keys with indication lights 4 The apparatus display 5 The reading 5 Choosing a technical or a reading 5 The technical reading 5 The reset key 5 Adjusting the flow water temperature 6 Adjusting the type of installation 6 Replenishing or complete filling up of the installation 7 Turning the apparatus off 7 2 ...

Page 4: ...ort of the apparatus for you as a user it can be beneficial to know about the operation of the apparatus Description of the apparatus The STREBEL S HR is a room sealed condensing and modulating central heating apparatus which is designed with or without hot water facility A built in ventilating fan sucks in the combustion air from outside and provides for a complete premixing of gas and air The ga...

Page 5: ...to prevent sticking when an outside sensor has been connected to the unit The circulation pump will start automatically when there is a chance of frost to prevent danger of freezing The efficiency of the apparatus is very high and the radiation convection and standby losses very low The emission of noxious substances is far below the fixed standards so the apparatus meets the requirements of the G...

Page 6: ...e apparatus is a revolving door You can already see a part of the control lights and the display through the dark transparant window After opening the door the control panel with the function keys is clearly visible The control panel is provided with a number of push buttons with corresponding lights The meaning of these push buttons is explained hereunder ...

Page 7: ...or heat Press this key in order to let the circulation pump circulate according to the automatic switch program or continually via the central heating installation The circulation pump will circulate continually via the central heating installation when the key is pushed and the indication light is illuminated In most situations the program can stay on automatic so that the circulation pump starts...

Page 8: ...mstances the display will give a reading and if a fault is established this will be reflected with the E for error and a certain number code Choosing a technical or a reading In order to switch from a reading to a technical reading for example the step key should be pushed for 5 seconds To return to the reading the step key should be pushed for 5 sec onds again display step key ...

Page 9: ...temperature of the apparatus In case of the reading the character P stands for pressure which represents the waterpressure Thethirdandfourthfigureindicatethewater pressureinbar Whenafault occurs it will be shown by the E of Error with a certain numbercode The Reset key The control panel is provided with a reset key When a fault occurs it will be shown by the flashing E of Error with a certain numb...

Page 10: ...e display will now show The first figure indicates which adjustment is being shown and the third and the fourth figure shows the value of this adjustment The standard adjustment is 85 C flow water temperature By means of the or key this value can be changed This changed value has to be stored by means of the store key If after this the mode key is pushed briefly the technical reading is shown agai...

Page 11: ...By means of the or the key the desired installation type can be chosen The choice has to be confirmed with the store key after which one can return by means of the mode key to the reading or the technical reading n o i t a l l a t s n I e c i o h c m e t s y s g n i t a e h l a r t n e c f o e p y t r e t a w w o l f e r u t a r e p m e t 1 s r o t c e v n o c g n i t a e h r i a d n a s r o t a i...

Page 12: ...e water pressure drops further and comes below 0 7 bar the display will show a flashing text The Brain thermostat will show the text Waterpressure too low disorder fill water After this the apparatus is switched off and will only function again when the waterpressure comes above 1 5 bar Turning the apparatus off Holiday period Adjust the Brain thermostat to the holiday period See the thermostat ma...

Page 13: ...Operating instructions S HR serial page 2 7 ...

Page 14: ......

Page 15: ...Operating instructions S HR serial page 2 8 The company reserves the right to change the specifications and dimensions without prior notice E O E ...

Page 16: ...on Name installator Place of business Person to be contacted Telephone number Telephone number after business hours 1F Albany park industrial estate Frimley road Camberley Surrey GU16 7BP Telephone 01276 685422 Fax 01276 685405 ...

Reviews: