Operating instructions S-HR serial page
2
The technical reading
During this reading the display will show in which operating status the
apparatus is active. The technical reading
is being repeated
every 2 seconds by the reading of the waterpressure
.
The first figure of the technical reading
indicates the status in
which the apparatus is active and the third and fourth figure indicate the
water temperature of the apparatus. In case of the reading
the
character P stands for pressure which represents the waterpressure.
The third and fourth figure indicate the water-pressure in bar. When a fault
occurs it will be shown by the E of Error with a certain numbercode.
The Reset key
The control panel is provided with a reset key. When a fault occurs it will
be shown by the flashing E of Error with a certain numbercode after which
the apparatus is shut down. After pressing the reset key you can try to
start the apparatus again. If the defect keeps returning contact your
installer.
reset
key
display
step
key
5