OS-15

15 gpm, 15 gallons

10 gallon oil capacity

1 gallon sand capacity

OS-25

25 gpm, 21 gallons

15 gallon oil capacity

6 gallon sand capacity

OS-35

35 gpm, 38 gallons

28 gallon oil capacity

6 gallon sand capacity

OS-50

50 gpm, 57 gallons

40 gallon oil capacity

7 gallon sand capacity

OS-75

75 gpm, 110 gallons

93 gallon oil capacity

11 gallon sand capacity

OS-100

100 gpm, 250 gallons

144 gallon oil capacity

95 gallon sand capacity

OS-500

100 gpm, 500 gallons

288 gallon oil capacity

95 gallon sand capacity

Sheet Descriptions

   

Sheet #1 - Series overview and Warranty information

Sheet #2 - OS General installation guidelines and Operation/Maintenance guidelines

Sheet #3 - Below Grade installation guidelines 

Sheet #4 - Below and Above Grade installation guidelines 

Sheet #5 - Multiple unit systems. Setting the oil draw off

Sheet #6 - OCT General installation guidelines and Operation/Maintenance guidelines 

Sheet #7 - TeleGlide Riser installation guidelines (SR24, LR24)

Sheet #8 - TeleGlide Riser installation guidelines (SR16)

Leak/Seal Testing

   

DO NOT AIR TEST UNIT OR TELEGLIDE RISER SYSTEM!  Doing so may result in property damage, personal injury or death.  

Base Unit:

  To perform a leak/seal test on the base unit, cap/plug all plumbing connections, remove the cover, and fill the unit with water just above the

highest connection. Inspect unit and connections for leaks. Check water level at specific time intervals per local code.  

TeleGlide Riser System:

  If required by local code, the riser system may be leak/seal tested similar to the base unit. 

CAUTION:

 the riser(s) must be supported

before filling with water to keep from tipping over. Once riser system is in place and properly supported, cap/plug all plumbing connections on the main unit,

remove the cover from the top of the riser assembly and fill the unit and riser system with water to finished grade level. Carefully, as the riser(s) will be very

heavy from the weight of the water, inspect all gasket(s) and clamps (if applicable) for any leaks. Check water level at specific time intervals per local code.

Lifetime Warranty

Effective March 2, 2015 Striem represents and warrants that HDPE and PP products will be free from any

and all defects in material and workmanship, including corrosion, during the lifetime of the plumbing system in which the Products were originally

installed and will, at its option, agree to repair, replace, or supply credit to the original purchaser.
This warranty does not cover damage caused by the Products’ normal usage, or wear and tear, nor does it cover damage from naturally occurring

phenomenon, including, but not limited to UV, freeze-related damage, or natural disasters. This warranty does not cover the purchaser’s cost of routine

maintenance including replacement of parts required in routine maintenance.
This warranty does not cover fabricated steel products, or any monitoring equipment. This warranty shall be effective if, and only if, the Products:

* Were installed in accordance with Striem’s notes, specifications and instructions, for installation, operation, and maintenance;

* Were installed in conformance with all applicable building and plumbing codes, and passed all applicable testing methods immediately following installation;

* Have not been subjected to misuse or abuse, whether negligent or intentional;

* Were never modified, repaired, or altered by any individual(s) not authorized by Striem.
This warranty is the purchaser’s sole and exclusive remedy, and acceptance of this exclusive remedy is a condition of the contract for thepurchase of these

Products. In no event shall Striem be liable for any incidental, special, consequential or punitive damages, or for any costs, attorney fees, expenses, losses or

delays claimed to be as a consequence of any damage to, failure of, or defect in any products including, but not limited to, any claims for loss of profi ts,

transportation, removal and installation charges. This warranty is exclusive and in lieu of all other warranties or conditions, written or oral, expressed or implied.

OIL RESERVE OIL SEPARATORS

(Models OS-15, OS-25, OS-35, OS-50, OS-75, OS-100, and OS-500)

OS & OCT SERIES INSTALLATION, 

OPERATION AND MAINTENANCE GUIDE

ECO:

8/15/18

MJ

REV:

DATE:

DWG BY:

DESCRIPTION:  

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF 

STRIEM, LLC. 

ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF 

STRIEM, LLC. 

IS 

PROHIBITED.

NOTES:

Striem oil separators are rated and manufactured with an internal flow control system already in 

place.  They do not require an external flow control system or air intake vent.

Striem oil separators are not to be installed in any other manner except as shown.  Consult local 

codes for separate trapping requirements, cleanout locations and additional installation instructions.

SHEET NUMBER: 

1 of 7

Summary of Contents for OS-15

Page 1: ... lifetime of the plumbing system in which the Products were originally installed and will at its option agree to repair replace or supply credit to the original purchaser This warranty does not cover damage caused by the Products normal usage or wear and tear nor does it cover damage from naturally occurring phenomenon including but not limited to UV freeze related damage or natural disasters This...

Page 2: ...to exceed no more than 6 months TROUBLESHOOTING TIPS In the case of a clog inlet and outlet diffusers may be removed for line cleaning Slower than usual drainage may indicate the need to pump clean oil separator Units with 6 connections have a removable plug on the back of the diffuser as the diffuser itself is not removable Always take proper care to ensure a safe and healthy environment while cl...

Page 3: ...6 deeper than tank bottom 3 Set the tank in well packed crushed aggregate material 4 approximately 3 4 size rock or sand with no fines When setting OS 75 2 and the OS 500 all units must be level Anchor kit is recommended for installations in high water table conditions to 5 prevent float out To be determined by specifying engineer If necessary order optional Anchor Kit See detail on this sheet BAC...

Page 4: ... unit s 1 Backfill using crushed aggregate 7 backfill material approximately 3 4 size rock or sand 2 with no fines 3 Place 6 aggregate base under slab Note Models OS 15 and OS 25 cannot be installed flush with floor A riser must be used for below grade installations INTERIOR ABOVE GRADE INSTALLATION INSTRUCTIONS OS 15 OS 25 OS 35 OS 50 OS 75 OS 100 OS 500 Install unit s as close as possible to fix...

Page 5: ...work properly the oil draw off must be adjusted to meet the correct operating height for the flow of the unit The oil draw off unit leads separated oil into an oil drainage line and collection tank where it can be taken care of properly See OCT Series Once the Oil Separator is installed an operating water level must be established Remove covers and run water through separator at maximum flow rate ...

Page 6: ...lled into the main unit this new line will end up at the top of the gasket and will aid in re assembly See Figure 3 IMPORTANT Before the next step 8 Make sure both diffusers are installed inside the main unit at the appropriate locations and check if there needs to be any flow control adjustment on the inlet diffuser Refer to sheet 2 of the installation instructions for flow control adjustment Ref...

Page 7: ...nge with 4 bolt notches faces down against the unit See Figure 1 Push riser into ring until it stops about 1 inch See Figure 2 4 Measure the distance from the top edge of the riser down to the finished floor Make sure to account for any future tile work 5 in your measurment See Figure 2 Remove riser from ring Take measurement from step 5 from the BOTTOM of the riser upwards towards the top of the ...

Reviews: