AUDACES
40
The software of
control center
could not be
started up.
1. Problems
with the software
or WINDOWS.
1. Reinstall the
software of the
plotter or
WINDOWS
software.
8.3 Plotter errors
Problems
Possible
reasons
Solutions
Indicator light of
ERROR is on all
the while.
1. The cover is
not put on
correctly.
1. Put on the cover correctly and
switch on the potter again.
2. Replace the switch of the
cover.
Indicator light of
ERROR is on for 2
seconds and off for
1 second. At the
same time, the
indicator light of
INKOUT is on
1. Short of ink
1. Replace the print-head.
Indicator light of
ERROR is on for 2
seconds and off for
1 second.
1. Errors
occur in the data
tablet.
1. Check whether the cable is
connected correctly.
2. Check whether the marker
files are correct.
Indicator light of
ERROR is on for
0.5 second and off
for 0.5 second.
1. X Motor
protects itself (be
not able to take
up paper for
some time).
1. Check whether the paper bail is
laid down.
2. Check whether the plotter is
out of plotting paper.
Indicator light of
ERROR is on for 5
seconds and off for
5 seconds.
1. The stated
length and width
is exceeded for
receiving data for
MPU1.
1. Check whether the marker
files are correct and whether the
width exceeds the range of the
plotter.
Indicator light of
ERROR is on for 1
second and off for
2 seconds.
1. Motor stops
operation and
protects itself due
to the outside
force/bump in Y
direction.
2. The
carriage does not
move to the
1. Check whether the surface of
slide guide is smooth, then wipe &
clean it with lubricating oil.
2. Check whether there obstacles
on the track of the carriage, and
remove them if there are.
3. Check whether the carriage has
been moved by hands before.
4. Switch on the plotter again.
Summary of Contents for AUDACES Jet Lux Plus