22
BA_KA-ED_A22_190313_en.doc
4.6.5
Button “1” on the V810 operating control (Fig. 10)
Button 1 can be used to interrupt the actual “sewing” without ending the automatic
sewing mode.
After switching off the function the actual sewing mode can be continued again by
pressing the START button S4 (on the switch box).
4.6.6
Button “2” on the V810 operating control (Fig. 10)
Button 2 can be used to switch the thread controller on and off.
During the sewing in automatic sewing mode the sewing thread is monitored for
breakage. In case of a thread break the machine stops in position 2 and the yellow
light L2 starts blinking.
4.6.7
Button “3” on the V810 operating control (Fig. 10)
Button 3 can be used to set the ratio of the carriage transport to the upper transport
(differential transport).
For the setting:
100
→
carriage transport equals upper transport (synchronous)
101-500
→
carriage transport is less than upper transport
000-099
→
carriage transport is greater than upper transport
4.6.8
Button “4” on the V810 operating control (Fig. 10)
Button 4 can be used to display or delete the counter status of the part counter.
Display the counter:
Press button 4
Delete the counter:
Keep button 4 pressed for about 5 seconds when the
counter is displayed.