Operation
6 — 4
05_0184_0802GB
"
Open the air supply to the pneumatic tool.
"
Adjust the working pressure using the ”working pressure”
handwheel.
"
Read the working pressure displayed on the ”working pres-
sure” gauge.
"
Check the tank pressure on the ”tank pressure” gauge.
Caution
The tank pressure must remain constant and should never fall below
5 bar.
Set the working pressure accordingly.
Preset the correct working pressure for the pneumatic tool in
question. The compressed air output depends on the preset
working pressure.
The following table contains general guide values for setting the
working pressure:
Working pressure
Strocomp 433
Strocomp 656
Strocomp 864 / 865
Small quantity of
compressed air
approx. 1.0 bar
approx. 1.0 bar
approx. 1.0 bar
Large quantity of
compressed air
max. 3.5 bar
max. 4.5 bar
max. 6.0 bar
The following guide values for setting the working pressure apply for
operation with Strobot delivery pumps:
Working pressure
Strocomp 433
Strocomp 656
Strocomp 864 / 865
Spraying fine plaster
1.5 to 2.5 bar
1.5 to 2.5 bar
1.5 to 3.0 bar
Spraying concrete
contact
1.0 to 1.5 bar
1.0 to 1.5 bar
1.0 to 1.5 bar
Spraying paint
2.0 to 4.0 bar
2.0 to 4.0 bar
2.0 to 5.0 bar
Note
There
are
specific
criteria
for
achieving
the
best
result
for
every
application.
Contact
Maschinenbau Rudolf GmbH
for
advice
on
the
correct
settings
for
your
specific
application.
Setting values