Summary of Contents for SEUS6L

Page 1: ...STROM ELECTRICAL www strom electrical com U n d e r s i n k O v e r s i n k H e a t e r I n s t a l l a t i o n M a n u a l I s s u e 1 2 0 1 6 2 0 1 7 STROM ELECTRICAL www strom electrical com ...

Page 2: ...be installed and maintained regularly by a qualified professional in accordance with current electrical and plumbing regulations The included Safety Pressure Relief Valve MUST be fitted in accordance with this manual Your Strom Electrical water heater MUST be installed in the correct orientation in accordance with page 5 The unit can be sited above or below the taps so long as it is in the correct...

Page 3: ...n from the heater to the system pipework should be made using flexible stainless steel hoses this facilitates the operation of the unit and also makes future maintenance easier The pipework used should be capable of withstanding 7 5 bar of working pressure and temperatures in excess of 80o C The included safety relief valve must always be fitted without exception and should have no obstructions wh...

Page 4: ...Vessel Check Valve Pressure Reducing Valve Heater Expansion Vessel Check Valve Closest Cold Draw Off Pressure Reducing Set Service Valve Not Supplied Discharge To Drain Heater Expansion Vessel Check Valve Closest Cold Draw Off Service Valve Not Supplied Discharge To Drain Heater Closest Cold Draw Off Service Valve Not Supplied Pressure Relief Valve Discharge To Drain Minimum Distance Required To P...

Page 5: ...sure your water heater is correctly earthed As previously recommended please ensure that you unit has been filled correctly flushed and all debris and airlocks have been removed before turning your water heater on By bypassing this step you risk irreversible damage to your water heater that will not be covered by your warrenty Electrical connections can be made via an external time clock if requir...

Page 6: ...l for maintenance Before attempting to maintain the unit please ensure you have isolated the electrical supply MAINTENANCE Before attempting to maintain the unit please ensure you have isolated the electrical supply and should only be performed by a qualified professional This unit is a mains pressure hot water unit and it is recommended that this device be serviced annually to ensure a long and h...

Page 7: ...ailed Please replace the thermostat Insufficient Amounts Of Hot Water Available The heater has been undersized Please replace the heater with one of an adequate size The unit has been mounted the wrong way round Please mount the heater ensuring the pipes are facing downwards The Thermostat has failed Please replace the thermostat The Unit Has Begun To Leak Faulty plumbing connection Please check a...

Page 8: ...STROM ELECTRICAL www strom electrical com w w w s t r o m e l e c t r i c a l c o m ...