Clutches with 2 slip rings (EDE/EDB)
SKB-0127
+
-
DD 501.028 - 002 / Fig. 8
For clutches with 2 slip rings, the current is returned via the second slip ring.
For operating voltages of over 60 V, the housing must be connected with an earth conductor. The requirements
for earth conductor connections according to DIN VDE 0580 must be observed. Continuous electrical connec-
tion must be secured between the housing and the clutch, by using adequate connecting elements.
25
Mounting instructions Electromagnetic multi-disc clutch EKE/EKB, EDE/EDB • No. 500-00000 C • 10/2017