Spa Maintenance

The maintenance and care of your spa is simple and easy to carry out, and if performed regu-
larly as scheduled, problems will be minimal.  It is  important that the following procedures be
read through and carried out on a regular basis for the best, long term, overall performance of
your spa.

The filtering cycle of your spa should be operated at least two hours or more a day (whether
or not the heater is heating) to remove impurities and to prevent disposition of contaminants
in your spa.  The filtering system works automatically.  Keep the spa covered when not in use
to reduce the loss of heat and to keep debris from settling in the water.

Maintaining the spa's proper water chemical balance is essential to the comfort and safety of
the user.  Water mineral content varies constantly and is directly affected by evaporation and
the use of cleaning and maintenance chemicals, which will increase mineral content, when
added.  If the mineral content deviates from prescribed pH level (7.2-7.8) deposits on the spa
walls, filter, electric heating element or gas heater manifold and piping may adversely affect
the condition of your spa equipment.

Since the water capacity of your spa is far less than that of a swimming pool, the chemical
reaction caused by the presence of one or more persons in the spa is more rapid and pro-
nounced.  In other words, it is much more difficult to maintain the proper pH balance in a spa
than in a swimming pool.  For these reasons, it is important to check frequently, the total alka-
linity of the water, the pH level, and the sanitize level, then add prescribed chemicals as nec-
essary to maintain the proper chemical balance.  Failure to maintain a proper balance of
chemicals in your spa will result in an early, premature failure of your spa parts including, but
not limited to, the spa cover, piping, certain electrical components in the spa, electrical control
box and topside panel, thus voiding the warranty.

YOUR SPA INCLUDES AN OZONATOR (240 volt Gold Edition only)
Ozone is injected into the spa's water during the filtration cycle and when heating in the
standard mode.  The ozone is injected into the water to supplement chemical sanitizers,
kill bacteria, oxidize organics and control minerals.  If in a filter cycle, anytime the pump is
manually turned on, the ozonator will turn off.  The ozonator will remain off until the start of
the next filter cycle or the next automatic pump function.

ESSENTIAL CHEMICALS AND THERE USE
The following information on chemical use for spa maintenance is provided strictly as a
guide for the spa owner and may or may not be appropriate to maintain your spa correctly
and may, under certain conditions, be harmful to your spa and/or persons using the spa.
Always check with your pool and spa dealer to determine which chemicals and/or proce-
dures they recommend to maintain your spa correctly.  STRONG POOLS and SPAS does
hereby claim no responsibility or liability for use of and quantities of the chemicals listed.

Summary of Contents for The Antigua

Page 1: ...MANUAL P O Box 108 Northumberland PA 17857 1 800 STRONG 9 1 800 787 6649 2 15 06 CAUTION More than one GFCI used on the electrical circuit will render this spa inoperable This spa must be on a dedicated circuit ...

Page 2: ...ble Shooting 7 8 Spa Maintenance 9 10 Jets Valves Injectors Suction 11 Warranties 12 Safety Precautions 13 Registration Card 13 Be sure to locate the Registration Form at the back of this owner s manual Please fill it out and send it to Strong Pools and Spas immediately Failure to return this registration card within 30 days of purchase voids all warranties provided by Strong Pools and Spas ...

Page 3: ...that Lasts a Lifetime With proper care operation and maintenance your spa will provide your family many years of comfort and pleasure Please take time to read all the instructions before you install your Strong Pools Spa Antigua spa This manual explains safety precautions installation instructions operating directions and maintenance procedures If you have any questions after reading this manual p...

Page 4: ...d 40 C 104 F and lower water temperature is recommended for extended use exceeding 10 15 minutes and for young children Long exposure at higher temperature can result in dizziness and or hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 F 36 7 C The symptoms of hyper thermia include dizziness fainting ...

Page 5: ...oom location landscaping and evening lighting The spa with water is very heavy if the spa is placed on flooring or decking be sure the structure is strong enough to support the weight The necessary support should be at least 75 pounds per square foot Install your spa in a way that will allow easy access to the equipment door Storage area for maintenance equipment and chemicals storing chemicals in...

Page 6: ...breaker must be dedicated and cannot be shared with any other appliances It should be labeled and easily accessible to users DO NOT USE EXTENSION OR PLUG TYPE CORDS OF ANY KIND The use of a shut off box near the spa is recommended Metal surfaces within 5 feet of the spa must be grounded to the spa A 120 Volt 15 Amp GFI rated plug is furnished with the Antigua Silver Spa CAUTION This spa will not w...

Page 7: ...ped with an LED Multi Color Light The colors will cycle as you press the light button on and off HEAT Press the Heat key to adjust the temperature Press once and hold will raise tem perature Press a second time and hold will lower temperature to the minimum set point of 70º F or 21º C A red LED will flash at the topside control when the heater is on There are FOUR unions that may require hand tigh...

Page 8: ...l operation to protect the system Upon power up the read out will display three digit software release This number will then change to 888 while the system is booting up After starting up the low speed pump will start running if the water temperature is below 100 F 37 8 C If a FL1 appears on the display turn the system off and repeat step 2 If the water temperature is below 55 F 12 8 C ICE will al...

Page 9: ... that the temperature sensing probe connected to the main board is clean and sound at location J1 Try new temperature sensing probe Display flashes th2 39 on system start up This indicates that both sensors thermisters are detecting tub water temperature of less than 39F or they are both disconnected open Pump s will run in this condition See Freeze Protect Override FPO instructions for cold water...

Page 10: ...opside control remove clean reconnect Try new topside control Replace main board Pump s blower or light does not shut off Try new topside control Replace main board Circulation pump does not work Check the fuse and power connections Light does not work Press Light to turn the light on off The Antigua Spa is equipped with an LED Multi Color Light The colors will cycle as you press the light button ...

Page 11: ...intain the proper pH balance in a spa than in a swimming pool For these reasons it is important to check frequently the total alka linity of the water the pH level and the sanitize level then add prescribed chemicals as nec essary to maintain the proper chemical balance Failure to maintain a proper balance of chemicals in your spa will result in an early premature failure of your spa parts includi...

Page 12: ...y compati ble with the other chemicals listed Use as recommended by the manufacturer SPA WATER should be changed periodically depending upon frequency of use and other conditions that may affect water suitability Typically 60 to 90 days is a satisfactory interval under normal conditions With heavy usage the interval between water changing should be less SPA FILTER CARTRIDGE should be cleaned every...

Page 13: ...r Control Valve Air Control Valve should be turned off when spa is not in use The spa will heat up faster Bottom Suction Turn counter cloc k w i s e t o o p e n Turn counter cloc k w i s e t o o p e n Turn counter cloc k w i s e t o o p e n Jets Valves Injection and Suction ...

Page 14: ...ue to obvious misuse NOTE the warranty begins from the date of delivery and is only valid to the original owner The warranty does not cover damage caused by neglect misuse improper hookup and water chemistry or leaving the empty spa exposed to the sun Pressure Switch adjust ments are covered for thirty 30 days from delivery Travel or mileage costs are not cov ered under these warranties and may be...

Page 15: ...Tub when others are present 2 Children should be supervised at all times 3 To avoid the risk of drowning keep the filter clean and unclogged Do not remove the suction drain cover Do not modify the suction or filtration systems 4 Exercise caution when entering or leaving the Hot Tub When changing positions be sure of your footing before applying your full weight as water refraction can be misleadin...

Page 16: ...NDAY THROUGH FRIDAY 8 30 AM 5 00 PM E S T 570 275 2700 GIVE YOUR NAME TELEPHONE NUMBER AREA CODE NAME OF SPA NAME OF MODEL QUANTITY AND TYPE OF PARTS REASON FOR REQUEST A DAMAGED B DEFECTIVE PLACE STAMP HERE STRONG POOLS SPAS 3204 Point Township Drive Rte 11 P O Box 108 Northumberland PA 17857 ...