Customer Service 1•800•787•6649
15
Operate Your Spa
The start-up temperature is set at 100°F/37°C.
The last measured temperature is constantly dis-
played on the LCD. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least 2 minutes.
To display the set temperature, press the
“Temp” pad once. To change the set temperate,
press the pad a second time before the LCD stops
flashing. The temperature will either go up or down.
To change the temperature in the opposite direc-
tion wait for the LCD to stop flashing, press the
“Temp” pad once, then press the “Temp” pad again
to reverse the temperature direction. After three
seconds, the LCD will stop flashing and display the
current spa temperature.
Maximum Temperature is set at 104ºF/40ºC
as required by UL/CSA.
Minimum temperature is 80ºF/26ºC.
Note: If the spa is currently in a heating or filtration
cycle the pump will only switch between high and low. It
cannot be turned off until the heating or filtration cycle
is completed.
Jets
Touch the “Jets” button once to turn the main
2-speed pump on or off, and to shift between low
and high speeds. If left running, the low speed of the
pump will automatically turn off after 2 hours, and
the high speed will automatically turn off after 15
minutes. The “Boost” button will operate the blower
pump, if equipped, or the 1-speed pump.
Light
Press “Light” button to turn the light on/off. If left
on, the light automatically turns off after 4 hours.See
page 25 for lighting specifics.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is
energized. The second filter cycle begins 12 hours
later. Filter duration is programmable for 2-(C)on-
tinuous per 12 hours. The default filter time is 2
hours.
Example 1: In a 12 hour period (1 cycle), a setting of F2
means 2 hours of filtration on, 10 hours of filtration off.
Example 2: In a 12 hour period (1 cycle), a setting of F4
means 4 hours of filtration on, 8 hours of filtration off.
You may choose F2, F4, F6, F8 or c (continuous).
To program, press “Temp” then “Jets”. Press “Temp”
to adjust. Press “Jets to exit.
Mode
Mode is changed by pressing the “Temp” button,
then pressing the “Light” button.
In Economy and
Sleep Mode, heating only occurs during the filter
cycle. See Mode, page 18.
Freeze Protection
If the temperature sensors detect a drop to below
44°F/6.7°C within the heater, the pumps will auto-
matically activate to provide freeze protection. The
equipment stays on until 4 minutes after the sensors
detect that the spa temperature has risen to
45°F/7.2°C or higher.
Control Pack Codes
See pages 19-23.
______________________________________
Two-Pump Spas and
Two-Pump + Blower Spas
System Settings
When your spa is first actuated, it will go into Prim-
ing mode, indicated by “Pr.” The Priming mode will
last for less than 5 minutes (press “Warm” or
“Cool” to skip Priming Mode) and then the spa will
begin to take temperature readings, followed by the
heater test cycle. After completed, the heater will
turn on, heat the spa and maintain the water tem-
perature in the Standard mode.
The start-up temperature is set at 100°F/37°C.
The last measured temperature is constantly dis-
played on the LCD. Note that the last measured spa
temperature displayed is current only when the
pump has been running for at least 2 minutes.
To display the set temperature, press the
“Warm” or “Cool” pad once. Each press of the
“Warm” or “Cool” pad will continue to either raise
or lower the set temperature. After three seconds,
the LCD will display the current spa temperature.
Summary of Contents for WK01S
Page 19: ...Customer Service 1 800 787 6649 19 Operate Your Spa Control Pack Codes ...
Page 20: ...20 www strongpoolsandspas com Operate Your Spa ...
Page 21: ...Customer Service 1 800 787 6649 21 Operate Your Spa ...
Page 22: ...22 www strongpoolsandspas com Operate Your Spa ...
Page 40: ...40 www strongpoolsandspas com ...
Page 57: ...Customer Service 1 800 787 6649 57 ...
Page 58: ...58 www strongpoolsandspas com ...