pg.4
SM-RAZOR-F Installation and Users Manual
INSTALLATION
Step 1: Mounting the Wall Bracket Assembly
For Mounting on a Stud Wall
For Mounting on a Concrete Wall
WARNING: When installing wall bracket on cinder block:
A. Pre-drill holes into two wood studs using a
3/16” drill bit. Be sure to drill into the center
of the studs at least 2-1/2” deep. The use of
a stud finder is highly recommended.
B. Insert the Lag screws (A) into holes through
the Wall Plate and tighten. (Figure 1).
WARNING: Tighten bolts so that wall plate
is firmly attached, but do not over tighten.
Over tightening can damage the bolts, greatly
reducing their holding strength.
• Verify first that you have a minimum of 1-3/8” of concrete thickness to be used
for the concrete anchors.
• Do not drill into mortar joints! Be sure to mount in a solid part of the block,
generally 1”minimum from the side of the block.
• Cinder block must meet ASTM C-90 specifications.
• It is suggested that a standard electric drill on slow setting is used to drill the
hole instead of a hammer drill to avoid breaking out the back of the hole when
entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not
hold anchors.
• Make sure that the supporting surface will safely support the combined load of
the equipment and all attached hardware and components.
Figure 1