Page 8 of 16
Minimum Wire Size Of Extension Cords
Nameplate AMPS
Cord Length
25' 50' 100' 150'
0-6
18 AWG
16 AWG
16 AWG
14 AWG
6-10
18 AWG
16 AWG
14 AWG
12 AWG
10-12
16 AWG
16 AWG
14 AWG
12 AWG
12-16
14 AWG
12 AWG
NOT RECOMMENDED
When using more than one extension cord to make up the total length, make sure each cord
contains at least the minimum wire size required.
If you are using one extension cord for more than one tool, add the nameplate amperes and use
the sum to determine the required minimum cord size.
If you are using an extension cord outdoors, make sure it is marked with the suffix
W-A
(
W
in
Canada) to indicate it is acceptable for outdoor use.
Make sure your extension cord is properly wired and in good electrical condition. Always replace
a damaged extension cord or have it repaired by a qualified electrician before using it.
Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.