4
TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION
Model of boiler
S7
S10
S12
S20
S30
S40
S7
BIO
S10
BIO
S12
BIO
S20
BIO
S30
BIO
S40
BIO
S10
U
S12
U
S20
U
S30
U
S40
U
Burning time of pellets, minimum
mode.
Maximum mode. ***
-
-
-
-
-
-
72
14
96
24
96
24
96
24
96
24
96
24
96
24
96
24
96
24
96
24
96
24
Burning time of coal, minimum
mode.
Maximum mode. ***
-
-
-
-
-
-
-
-
-
-
-
130
32
130
32
130
32
130
27
130
27
Firewood length up to (cm)
35
35
45
45
55
55
35
35
45
45
55
55
35
45
45
55
55
Boiler water amount (l)
15
22
32
40
42
52
15
22
32
40
42
52
22
32
40
42
52
Efficiency (%)
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
Pressure safety valve (bar)
1,5
1,5
1.5
1,5
1.5
1,5
1,5
1,5
1.5
1,5
1.5
1,5
1,5
1.5
1,5
1.5
1,5
Chimney draught (mbar)
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,12
Maximum heated water flow
(l/h)
200
250
300
500
800
1000
200
250
300
500
800
1000
250
300
500
800
1000
Lowest boiler water temperature
(°C)
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
Minimum chimney flue area
(cm
2
)
150
200
250
250
330
330
150
200
250
250
330
330
200
250
250
330
330
Chimney diameter (mm)
160
180
180
180
200
200
160
180
180
180
200
200
180
180
180
200
200
Distance between ground and the
chimney (mm)
991
1413.5
1302
1550
1285
1549
991
1413.5
1302
1550
1285
1549
1494
1302
1673.5
1285
1664
Dimensions (mm)
(1900)
(1900)
(1900)
(1900)
(1900)
(1900)
h
d
1330
450
1900
450
1700
550
2100
550
1700
670
2100
670
1330
450
1900
450
1700
550
2100
550
1700
670
2100
670
1900
450
1700
550
2100
550
1700
670
2100
670
Weight (kg)
134
158,5
193
218,5
258
318
140
165,5
211
236,5
284,5
344,5
177
213
243
297,5
345,5
* Power depends on the quality of fuel and time: at the beginning of burning power output is
higher than indicated in the table, boiler puts out smoke that is hotter than 300 °C, therefore raisin
residues burn out, flue gets warmed up and draft increases (in some models, direct channel to flue
is opened). While burning, power of boiler decreases because the surface of heat dissipation
increases and draft decreases, but when a house becomes warm the power is sufficient and
additional valve is opened in order to further decrease the power of boiler.
** Power of boiler is selected according to area of premise. For example, if in Stropuva S20
solid fuel boiler built in 200 m
2
building with one load burns 24 hours, then one load of firewood in
Stropuva S40 solid fuel boiler would burn for almost 48 hours.
*** Burning duration depends on fuel quality, inner and outer temperature, thermal resistance,
boiler power, manual compliance (installation, heated water flow, water temperature maintenance).