BM77
Skip to STEP 8 if you have the
D1060UG Backhoe.
STEP 7.
Once hoses are properly
routed, connect your D1060 Backhoe
hoses. Use the steps below and the pic-
tures on the next page as a guide.
1. Connect your #1770 Power Be-
yond Line as shown to the backhoe
valve.
Tighten with wrench!
2. Connect your #1774 Tank Re-
turn Line as shown.
Tighten fitting as
shown, then tighten hose clamp!
3. Connect your #1733 Pressure
Line as shown to the backhoe valve.
Tighten with wrench! Move to STEP
17.
STEP 8.
Once hoses are properly
routed, connect your D1060UG Backhoe
hoses. Use the steps below and the pic-
tures on the next page as a guide.
1. Connect your #1770 Power Be-
yond Line as shown to the backhoe
valve.
Tighten with wrench!
2. Connect your #1774 Tank Re-
turn Line as shown.
Tighten fitting as
shown, then tighten hose clamp!
3. Connect your #133 Pressure
Line as shown to the backhoe valve.
Tighten with wrench!
D1060UG
D1060
1774
TANK
RETURN
LINE
1774
TANK
RETURN
LINE
1770
POWER
BEYOND
LINE
1733
PRESSURE
LINE
(From
Pump)
1770
POWER
BEYOND
LINE
(To At-
tachment
Valve)
1733
PRESSURE
LINE
(From
Pump)