OVERVIEW / COMPLIANCE / WARNINGS / PRECAUTIONS 

OVERVIEW 

 



These cases should be installed and operated 
according to these instructions to insure proper 
performance.  Improper use will void warranty. 



This unit is designed for the display of products in 
ambient store conditions where temperatures and 
humidity are maintained at a maximum of 75 °F 
and 55% relative humidity. 

 

COMPLIANCE 

 



Performance issues when in violation of applicable 
NEC, federal, state or local electrical codes are not 

WARNING  

  

Risk of electric shock.  

Disconnect ALL ELECTRICAL SOURCES before servicing. 

 

WARNING 

ELECTRICAL 

  HAZARD

 

COMPLIANCE 

 

This equipment MUST be installed in compliance with 

all applicable NEC, federal, state and local  

electrical and plumbing codes. 

CAUTION 

CAUTION 

 

Fluorescent lamps have been treated to resist breakage  

and must be replaced with similarly treated lamps. 

CAUTION 

 

LED lamps reflect specific size, shape and overall design.   

Any replacements must meet factory specifications. 

CAUTION 

CAUTION 

 

If N.E.C. (National Electric Code) or your local code                                   

requires GFCI (Ground Fault Circuit Interrupter) protection,                            

the use of a GFCI breaker is strongly recommended. 

covered by warranty. 



See compliance specifics below. 

 

WARNINGS 

 



Following are important warnings to prevent 
injury or death. 



Please read carefully! 

 

PRECAUTIONS 

 



Following are important precautions to prevent 
damage to unit or merchandise. 



Please read carefully! 

Summary of Contents for Harmony HMG2653

Page 1: ...FRIGERATED CASES 33 DEEP SERVICE NON REFRIGERATED HMG L 53 PLEASE NOTE THE FOLLOWING 1 YOUR SPECIFIC MODEL NUMBER IS ON THE SERIAL LABEL ON CASE REAR NEAR MAIN POWER SWITCH 2 SEE MODELS AND THEIR RESP...

Page 2: ...ITS CASTERS ADJUSTING FRONT TOE KICK INSTALLATION FIELD WIRING CONNECTIONS FOR VARIOUS MODELS INSTALLATION FRONT GLASS ALIGNMENT ADJUSTMENT INSTALLATION DISPLAY CASE START UP INSTALLATION RAISING THE...

Page 3: ...ensions Note 3 If your specific model is not found contact technical service phone number is listed at Technical Service section in this manual for dimensions Note 4 CDRs Customer Design Requests are...

Page 4: ...CE This equipment MUST be installed in compliance with all applicable NEC federal state and local electrical and plumbing codes CAUTION CAUTION Fluorescent lamps have been treated to resist breakage a...

Page 5: ...d Maintain support of case at all times or center of gravity may cause case to fall Unlock Casters Roll unit to rear of skid Ramp Roll down ramp and off from skid Support while rolling case down ramp...

Page 6: ...of the 5 to 8 bolts in a cross wise pattern Work your way around the pattern tightening more firmly at each pass Do not firmly tighten one bolt and then start on the next H After the cases are bolted...

Page 7: ...from slot empty and replace See cleaning schedule for specifics on cleaning D Collapsible Rear Ledge When not in use lift up and allow support rod to collapse Lower ledge downward Reverse this procedu...

Page 8: ...ram Each case has its own wiring diagram folded and in its own packet Wiring diagram placement may vary it may be placed near condenser fan cover ballast box raceway cover or other related location 11...

Page 9: ...trip PVC Wireway HMG2653R Only Ballasts 13 Field Wiring Connections HMG7553 Field wiring connection junction box is at case rear underside See illustration below Single phase leads are provided Option...

Page 10: ...compromise the environment inside the case and may create condensation Follow the five steps listed below to assure proper front glass alignment 2 Front to Back Leveling Place a level on top of case p...

Page 11: ...r See illustrations below All lights should come on at same time First Light Switch time lighting may require a short warm up period for the bulbs Slightly dim or a flickering of new bulbs is normal T...

Page 12: ...nal position See illustration below View of Rear Doors being lifted up pivoted out and away from case View of Curved Glass being raised 18 Removing the Rear Doors Note Optional Swinging Door are on HM...

Page 13: ...llation of lamp Align pins with slot Insert pins into socket by rotating the bulb 1 4 turn to secure either the upper or lower pinned contacts into the sockets Rotate the remaining bulb contacts 1 4 t...

Page 14: ...ations at right 2 Plug and Cord Positioning Plug is to connect to LED light at raceway side of case Before attaching LED light to case verify that plug connects to LED properly without cord doubling b...

Page 15: ...with a household or commercial cleaner X Vacuum under case to remove all dust and dirt that may collect under case Clean Case Interior X Glass shelves can be cleaned with a household or commercial gla...

Page 16: ...orm this task Confirm that unit has been field wired correctly Caution Only a certified electrician is to perform this task Case Lights Not Working Check that ALL lights are plugged in and or receptac...

Page 17: ...ions on contacting Structural Concepts Technical Service Department See images below for samples of both refrigerated and non refrigerated serial labels Sample Serial Label For Non Refrigerated Case S...

Page 18: ...defined herein suffered or incurred by SCC as a result of or in connection with any act omission or use of the Goods by Purchaser its employees or customers or any breach of this Agreement by Purchas...

Reviews: